Installation Area; Floor Plan (Printer Area) - Stratasys J826 Site Preparation Manual

Hide thumbs Also See for J826:
Table of Contents

Advertisement

Stratasys J826

Installation Area

The installation area should be free of sources of vibration and electromagnetic interference that could
affect the proper functioning of the printer.
The floor gradient should be less than 0.5% (5 mm per meter).
The floor should be stable and able to bear the load of the printer. The minimum floor load is 630 kg/m
2
(129 lb/ft
).
The server workstation and the printer should be located in the same room.
The cable between the server workstation and the printer should not exceed 5 meters (16 feet). The
communication cable provided should not be extended or replaced with a longer cable.
Clearance around and above the printer should ensure convenient access and servicing.
The area around the printer should remain dry at all times. Do not place the cleaning station within
5 meters (16 feet) of the printer.
Shelves and cabinets are recommended near the printer for convenient storage of tools, parts,
accessories, manuals, and materials.

Floor Plan (Printer Area)

The following is a sample floor plan, showing the 3D printing system—the printer, the materials cabinet,
and the workstation. The dimensions shown in the figure are the minimum clearance requirements.
©
DOC-18005 Rev. E
2019-2020 Stratasys. All rights reserved.
Figure 4 Printer floor plan (sample, not to scale)
Installation Area
2
10