Store the machine:
• with the cutting means assembly lowered;
• in a dry place;
• protected from inclement weather;
• covered with a sheet if possible;
• in a place out of children's reach;
• making sure that keys or tools used for maintenance are
removed.
Before starting to use the machine again:

8. TROUBLESHOOTING

PROBLEM
1. With the key set to 'RUN',
the indicator light remains
off (only for models with
rear grass catcher)
2. With the key set to 'START',
the indicator light flashes
and the starter motor does
not turn (only for models
with rear grass catcher)
3. With the key set to 'START',
the indicator light turns on
and the starter motor does
not turn (only for models
with rear grass catcher)
4. With the key set to 'START',
the starter motor does not
turn (only for models
with side discharge)
5. With the key on «START»
the starter motor runs but
the engine does not start
• check that there are no fuel leaks from the tubes, fuel
• prepare the machine as described in chapter "5 Use of
NOTE Ensure that the battery is fully charged at least once a
month and always before use.
NOTE Store the machine so as to avoid any risk in the event
of accidental contact with people, children or animals.
PROBABLE CAUSE
The safety device of the electronic
circuit board has cut in due to:
badly connected battery
battery terminals inverted
flat battery
fuse blown
wet circuit board
no start-up consent
insufficiently charged battery
starter relay malfunction
no start-up consent
badly connected battery
battery terminals inverted
flat battery
fuse blown
wet circuit board
starter relay malfunction
insufficiently charged battery
faulty fuel supply
faulty ignition
EN - 9
stopcock or carburettor:
the machine".
Turn the ignition key to
«STOP» position and look for
the cause of the problem:
check the connections (par. 3.4)
check the connections (par. 3.4).
recharge the battery (par. 6.4)
Replace the fuse (10 A).
dry using lukewarm air
check that all starting conditions are
met (par. 5.2)
recharge the battery (par. 6.4)
contact your Dealer
Turn the ignition key to
«STOP» position and look for
the cause of the problem:
check that all starting conditions are
met (par. 5.2)
check the connections (par. 3.4)
check the connections (par. 3.4)
recharge the battery (par. 6.4)
replace fuse (10 A)
dry using lukewarm air
contact your Dealer
recharge the battery (par. 6.4)
check the level in the tank (par. 6.1)
open the fuel tap (if available)
check the fuel filter
check that the spark plug
cap is securely fitted
check that the electrodes are
clean and have the correct gap
SOLUTION