Roland DXY-1300 Command Reference Manual page 120

X-y plotter
Table of Contents

Advertisement

• Y-connection setting
To use the Y-connection, turn ON DIP Switch 2-(4) of the DXY-1000 series first and then
turn ON the power switch next. In this condition, all the data is transmitted from the host
computer to the terminal or vice versa without passing through the I/O buffer. At this
time, the DXY-1000 series only transmits the data but does no drawing.
When it receives the ESC.Y or ESC.( command, the DXY-1000 series stores data in the
I/O buffer and starts drawing according to the data Obviously the data being transmitted
here must be drawing data, and they can be output to the terminal. The way the drawing
data are output to the terminal varies depending on the 2nd bit to 3rd bit of the second
parameter of ESC.@ command as shown in Table 5-3 (Monitor mode OFF, monitor
mode 1, monitor mode 2).
The way your computer responds to a request of the DXY-1000 series varies depending
on whether the request comes from an RD-GL I command or a device control com
mand. In fact, it varies from the 2nd bit to 3rd bit of the second parameter of ESC.@ com
mand as shown in Table 5-3. In this condition, data from the terminal can be sent to the
computer. But when the DXY-1000 series is responding to the computer, this response
has first priority and the data from the terminal are ignored.
Also, when it receives the ESC.Z or ESC.) command, the DXY-1000 series returns to the
same condition as before it received the ESC.Y command or ESC.( command.
2nd
parameter
ESC
command
Before receiving
ESC.Y or ESC. (
or after receiving
ESC.Z or ESC. ).
Alter receiving ESC.
Y or ESC. ( .
How to output a response to a
request by a device control
command.
How to ou t p u t a response to a
request by a RD-GL I com
mands.
Monitor mode OFF
ESC.@;0:
of
or
ESC. @;4:
Output all data to a terminal including device control commands. (Output ESC.Y and
ESC .( too . }
Does not output to a termi
nal.
Output data to a host computer.
Output data to a host com­
puter.
Monitor mode 1
ESC.@:8:
Output data other than
those of device control
commands to a terminal
(1)
Output data to both host computer and terminal.
5-6
Monitor mode 2
ESC.@;I2:
Output data, including tho
se of device control comm
ands, to a terminal (2).

Hide quick links: