Temperature range
Ambient temperature range
Software variant
K-Value
ATEX marking
ATEX certificate
Gross volume
Net volume
Dimensions – H x B x D
Refrigerant
Refrigerant charge
Refrigeration capacity at -10°C
GWP – CO2e
Energy consumption –
default setpoint
Heat emission 100%
Heat emission default setpoint
Nominal consumption
Start current
Sound level
Data
+2/+20°C
+10/+43°C
K2+
0.31 W/(m2*K)
II 3G Ex nA nC nL llB T6 Gc
583 litres
419 litres
695 x 875 x 1874/2075 mm
R600a
102 g
354 Watt
N/A
1.15 kWh/24h
205 Watt
48 Watt
291 Watt
9.3 A
44.2 dB(A)
BioCompact II RR610G
Glass door
Technical specifications
Temperature range
Ambient temperature range
Software variant
K-Value
ATEX marking
ATEX certificate
Gross volume
Net volume
Dimensions – H x B x D
Refrigerant
Refrigerant charge
Refrigeration capacity at -10°C
GWP – CO2e
Energy consumption –
default setpoint
Heat emission 100%
Heat emission default setpoint
Nominal consumption
Start current
Sound level
b i o l i n e
Data
+2/+20°C
+10/+38°C
K6+
0.46 W/(m2*K)
II 3G Ex nA nC nL llB T6 Gc
583 litres
419 litres
695 x 875 x 1874/2075 mm
R600a
102 g
354 Watt
N/A
1.9 kWh/24h
240 Watt
79 Watt
315 Watt
8 A
44.2 dB(A)