BioCompact II RF210G
BioCompact II RF210G
Solid door
Technical specifications
Temperature range
Ambient temperature range
Software variant
K-Value
ATEX marking
ATEX certificate
Gross volume
Net volume
Dimensions – H x B x D
Refrigerant
Refrigerant charge
Refrigeration capacity at -25°C
GWP – CO2e
Energy consumption –
default setpoint
Heat emission 100%
Heat emission default setpoint
Nominal consumption
Start current
Sound level
Data
-25/-5°C
+10/+35°C
F52
0.35 W/(m2*K)
II 3G Ex ec nC ic llB T3 Gc
DTI 21ATEX0160X
125 litres
104 litres
595 x 640 x 801/1001 mm
R600a
30 g
156 Watt
N/A
1.53 kWh/24h
146 Watt
64 Watt
144 Watt
8.6 A
39.7 dB(A)
BioCompact II RF310G
BioCompact II RF310G
Solid door
Technical specifications
Temperature range
Ambient temperature range
Software variant
K-Value
ATEX marking
ATEX certificate
Gross volume
Net volume
Dimensions – H x B x D
Refrigerant
Refrigerant charge
Refrigeration capacity at -25°C
GWP – CO2e
Energy consumption –
default setpoint
Heat emission 100%
Heat emission default setpoint
Nominal consumption
Start current
Sound level
b i o l i n e
b i o l i n e
Data
-25/-5°C
+10/+35°C
F52
0.35 W/(m2*K)
3G Ex ec nC ic llB T3 Gc
DTI 21ATEX0160X
218 litres
189 litres
595 x 640 x 1190/1390 mm
R600a
35 g
204 Watt
N/A
1.69 kWh/24h
142 Watt
71 Watt
143 Watt
8 A
39.9 dB(A)
63
63
Need help?
Do you have a question about the BioCompact II and is the answer not in the manual?