Solid door
Technical specifications
Temperature range
Ambient temperature range
Software variant
K-Value
ATEX marking
ATEX certificate
Gross volume
Net volume
Dimensions – H x B x D
Refrigerant
Refrigerant charge
Refrigeration capacity at -25°C
GWP – CO2e
Energy consumption –
default setpoint
Heat emission 100%
Heat emission default setpoint
Nominal consumption
Start current
Sound level
58
Data
-25/-5°C
+10/+35°C
F52
0.35 W/(m2*K)
II 3G Ex ec nC ic llB T3 Gc
DTI 21ATEX0160X
2 x 125 litres
2 x 104 litres
595 x 640 x 1602/1802 mm
R134a
140 g
149 Watt
200.2
3.9 kWh/24h
320 Watt
81 Watt
316 Watt
11.8 A
42.1 dB(A)