Sencore AG 6000 User Manual page 120

Opengear 4k/uhd receiver decoder
Table of Contents

Advertisement

Default IP Address:
The CRD 1900 chassis will come configured to a static IP address that is accessible
through the RJ45 management port. It is configured with the following parameter
settings:
Parameter
Setting
IP address
10.0.20.101
Subnet Mask
255.255.0.0
address
Gateway
10.0.20.1
How to Reset to Default IP Address:
If the IP of the unit is unknown the default IP address may be reset. To reset the unit to
the default IP, the following steps are provided:
1. Remove the front panel of the CRD 1900 chassis to reveal the AG 6000 card.
2. Power on the CRD 1900 chassis and AG 6000 card, it will take about 3 minutes
to fully power on.
a. Hold the black button on the card edge until the red LED turns off.
i. If the button is held until the blue LED blinks, the card will be sent
b. The card is now processing the reboot function, this should take about 5
minutes to complete.
3. Once the card is fully rebooted, the default IP settings are configured.
a. Using the management port, the default IP address above will be
accessible.
Page 120 (122)
AG 6000 – User Manual
Description
This setting is the TCP/IP address assigned
to the port.
This setting is the subnet mask assigned to
the port.
This setting is the gateway address
assigned to the port.
into recovery mode. The card can be rebooted to revert this
process.

Advertisement

Table of Contents
loading