Sencore Impulse 300D User Manual

Sencore Impulse 300D User Manual

Network decoder

Advertisement

Quick Links

Impulse 300D
Network Decoder
User Manual
June 2021
Form 8222
www.sencore.com | 1.605.978.4600
Revision 1.0

Advertisement

Table of Contents
loading

Summary of Contents for Sencore Impulse 300D

  • Page 1 Impulse 300D Network Decoder User Manual June 2021 Form 8222 www.sencore.com | 1.605.978.4600 Revision 1.0...
  • Page 2 This document may also have links to third-party web pages that are beyond the control of Sencore. The presence of such links does not imply that Sencore endorses or recommends the content on those pages. Sencore acknowledges the use of third-party open source software and licenses in some Sencore products.
  • Page 3 Impulse 300D – User Manual Revision History Date (MM/DD/YYYY) Version Description Author 03/16/2021 Initial Release Page 3 (67)
  • Page 4 • Replacement Parts: When replacement parts are required, be sure the service technician uses replacement parts specified by Sencore, or parts having the same operating characteristics as the original parts. Unauthorized part substitutions made may result in fire, electric shock or other hazards.
  • Page 5 (at the breaker) and send your equipment to be serviced by a qualified technician. • To reduce the risk of shock the IMPULSE 300D must be connected to a mains socket outlet with a protective earthing connection. •...
  • Page 6 Impulse 300D – User Manual FCC Class A Information The IMPULSE 300D has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 7 Impulse 300D – User Manual Package Contents The following is a list of the items that are included along with the IMPULSE 300D: 1. AC Power Cable 2. Quick Start Guide Note: If any option cables were ordered with the IMPULSE 300D, they will be included in the box as well.
  • Page 8: Table Of Contents

    Configuring Static IP Address/Subnet Mask/Gateway ......... 19 Section 4 Operating the Web Interface ............20 IMPULSE 300D Web Interface Overview ..............21 4.1.1 Logging into the IMPULSE 300D Web Interface ..........21 4.1.2 Hiding Unused Inputs ................... 21 4.1.3 Buttons and Status Indicators................22 Main Panel .........................
  • Page 9 Impulse 300D – User Manual – Open Source Software ............64 Appendix D – Warranty ................66 Appendix E – Support and Contact Information ........66 Appendix F Page 9 (67)
  • Page 10: Section 1 Overview

    Impulse 300D – User Manual Section 1 Overview Introduction This section includes the following topics: Product Introduction ....................11 Front Panel Overview ....................11 Rear Panel Overview ....................12 Cooling ........................12 Rack Information ......................12 Page 10 (67)
  • Page 11: Product Introduction

    Front Panel Overview The IMPULSE 300D can be controlled from the front panel using the LCD screen and buttons that are shown below. A detailed description of using the front panel can found in Section 3.1. All hardware listed below comes standard.
  • Page 12: Rear Panel Overview

    5. RCA connection for Analog Audio 6. HDMI Output Connector Cooling The IMPULSE 300D is cooled via forced induction through the front of the unit and exhausted through the vents in the rear of the chassis. Rack Information The IMPULSE 300D is versatile and was designed to be deployed as a standalone device for easy installation into locations with limited space.
  • Page 13: Section 2 Installation

    Impulse 300D – User Manual Section 2 Installation Introduction This section includes the following topics: Rack Installation ......................14 Power Connection ..................... 14 AC Power Connection ....................14 Maintenance ......................14 Page 13 (67)
  • Page 14: Rack Installation

    IMPULSE 300D, personnel, or property. AC Power Connection The IMPULSE 300D is intended for use on either 120V or 240V systems. The power supply will automatically detect the system it is connected to. To hook up the power use the following steps: 1.
  • Page 15: Section 3 Operating The Front Panel

    Impulse 300D – User Manual Section 3 Section 3 Operating the Front Panel Introduction This section includes the following topics: IMPULSE 300D Front Panel Overview ..............16 Network Setup via Front Panel .................. 17 Page 15 (67)
  • Page 16: Impulse 300D Front Panel Overview

    The screen below is the idle screen of the IMPULSE 300D. This idle screen shows the incoming bitrate of the active input and output as well as the management IP addresses of the unit.
  • Page 17: Network Setup Via Front Panel

    The IMPULSE 300D can be setup on a network connection to allow remote management and SNMP configuration. For these features to work, the network settings for the IMPULSE 300D must first be configured properly for the network it is connected to. By default, the IMPULSE 300D follows this configuration scheme: •...
  • Page 18 Impulse 300D – User Manual 3. Use the buttons to Admin ↔↕ move the cursor to “Unit >Unit Networking Profile Networking”, then press the button. 4. Use the buttons to Unit Networking ↔↕ move the cursor to “Network 1 >Configure Networking Network 1 Configuration Configuration”, then press the...
  • Page 19: Configuring Static Ip Address/Subnet Mask/Gateway

    Impulse 300D – User Manual 3.2.2 Configuring Static IP Address/Subnet Mask/Gateway 1. If it is not already selected, use the Adapter Config 1 ↔↕ buttons to move the IP Mode: Static cursor to “IP”, then press the >IP: 0.0.0.0 Mask: 0.0.0.0 button to select it.
  • Page 20: Section 4 Operating The Web Interface

    Impulse 300D – User Manual Section 4 Operating the Web Interface Introduction This section includes the following topics: IMPULSE 300D Web Interface Overview ..............21 Main Panel ......................... 23 Admin Panel ......................38 Reporting Panel ......................49 About Panel ....................... 54...
  • Page 21: Impulse 300D Web Interface Overview

    Impulse 300D – User Manual IMPULSE 300D Web Interface Overview 4.1.1 Logging into the IMPULSE 300D Web Interface To open the IMPULSE 300D web interface use one of the following supported browsers and navigate to the unit’s IP address: • Internet Explorer •...
  • Page 22: Buttons And Status Indicators

    To minimize the status windows again click icon. Status in the IMPULSE 300D web interface is shown with LED status indicators: Status is good. No errors are present and function is operating Green LED normally.
  • Page 23: Main Panel

    Impulse 300D – User Manual Main Panel The Main panel of the IMPULSE 300D web interface is used to configure the unit to decode and de-encapsulate. When configuring the IMPULSE 300D the user begins at the top of the menu and works down. The inputs are configured, then decoding, baseband processing, then outputs are configured.
  • Page 24: Configuring Active Inputs

    Impulse 300D – User Manual 4.2.1 Configuring Active Inputs This menu allows the user to configure a input selection. Even though other inputs may receive a signal, the active input will be the only information shown in the decoding menu.
  • Page 25: Configuring Ip Receive/Input

    This menu configures the MPEG/IP input for reception of unicast or multicast transport streams. The version of IGMP the IMPULSE 300D uses is automatically determined when it connects to the network. IGMP Filter Mode can be entered for use when the unit is connected to an IGMPv3 network.
  • Page 26 Impulse 300D – User Manual Mode Multicast Multicast setting allows the unit to receive multicast streams. Multicast streams Unicast originate from the IP range 224.0.0.0 – 239.255.255.255. Unicast allows the unit to receive unicast streams. Unicast streams originate directly from a source device.
  • Page 27 Impulse 300D – User Manual MPEG/IP Input Statistics Menu button is used to reset all the statistics for incoming IP packets and establish a new point of reference. Page 27 (67)
  • Page 28 Impulse 300D – User Manual 4.2.2.2 Configuring HLS Input This menu configures the HLS input for reception of HTTP streams. The HLS input may be configured to receive through a local or network location through the HLS mode settings. General options for HLS input...
  • Page 29 Impulse 300D – User Manual Decryption Key User Entry Provides the key to allow signal processing if decryption is to be done Defines the length of time to wait for the Discovery Timeout 0 (infinite) stream to be discovered 1 – 100 (seconds) Click the icon by the HLS input to view information about the incoming IP stream.
  • Page 30 Impulse 300D – User Manual 4.2.2.3 4.2.2.3 Configuring SRT Input This menu configures the reception of a SRT input. The SRT input can be configured to specify a caller, listener or rendezvous within the Call Mode selection drop down. Setting...
  • Page 31 Impulse 300D – User Manual Local Port Mode Exclude In Auto Mode the local port number will be assigned Include In Manual Mode the local port number will be defined by the user Local Port 1 - 65535 Defines local port number...
  • Page 32 Impulse 300D – User Manual 4.2.2.4 Configuring Zixi Input This menu configures the reception of Zixi input. The Zixi input can be configured via a remote host. Setting Range Description Receive Enabled Enable/Disable the Zixi Input Disabled Interface Network 1...
  • Page 33 Impulse 300D – User Manual 1 – 128 characters Password Password to protect the stream. Ignore TLS Ignore Zixi Ignore TLS Certificate Error Certificate Error Do Not Ignore 30 – 10000 ms Maximum Latency Maximum latency or buffer size in...
  • Page 34: Configuring Video Services

    Impulse 300D – User Manual 4.2.3 Configuring Video Services The menu allows the user to configure both HDMI and SDI output formats of the IMPULSE 300D. The Auto setting may be used to match the native video format. General and Overlay Options Setti Range...
  • Page 35: Configuring Composite Output

    4.2.4 Configuring Composite Output This menu allows the user to configure the composite video output of the Impulse 300D. Color subcarriers and VBI embedding are configured in this menu. Please note that the composite video output is only active if the output video format is SD.
  • Page 36: Configuring The Mpeg/Ip Transmit

    Impulse 300D – User Manual 4.2.5 Configuring the MPEG/IP Transmit This menu allows the user to configure the MPEG/IP output. The two network ports can be set to either receive or transmit MPEG/IP. This menu is for setting up the transmission of MPEG/IP unicast or multicast transport streams.
  • Page 37 0.0.0.0 – Source IP Source IP for stream 255.255.255.255 Source Port 0 - 65535 This is the port used by the IMPULSE 300D to transmit the MPEG/IP stream. Enables automatic or manual source MAC Source MAC Mode Auto address input Manual 00:00:00:00:00:00 –...
  • Page 38: Admin Panel

    Impulse 300D – User Manual Admin Panel To access the Admin Control Panel, click on the tab. This menu allows the user to control many aspects of the IMPULSE 300D. Page 38 (67)
  • Page 39: Changing Unit Password

    4.3.2 Profiles The IMPULSE 300D has the ability to save all configured settings to multiple profiles. Profiles can be saved locally, renamed and saved to external storage to be used on other IMPULSE 300Ds. Profiles can be used to quickly and easily change the configuration of an IMPULSE 300D to suit different inputs and decoding requirements.
  • Page 40: Diagnostics

    4.3.3 Diagnostics The IMPULSE 300D provides the user the ability to take a snapshot of ALL current unit settings, reported values, active alarms, and the alarm and log file history. This snapshot will be downloaded as a .XML format file that can be sent to Procare at Sencore for analysis.
  • Page 41: General Settings

    Impulse 300D – User Manual 4.3.4 General Settings The IMPULSE 300D can be assigned an alias which is displayed in the upper right hand corner of the web interface. The alias can help define which IMPULSE 300D the operator is currently logged into.
  • Page 42 0 through 9 - (hyphen) Mode DHCP Setting to DHCP will allow the network assign an IP address automatically to the IMPULSE 300D Static (if supported). Setting to Static allows the user to manually define all TCP/IP settings for the management port.
  • Page 43: Ssh Tunnels

    4.3.6 SSH Tunnels The IMPULSE 300D can be remotely managed by using an SSH tunnel. In applications where Zixi ZEN Master is being used, an SSH tunnel is established to provide remote access to the web GUI of the IMPULSE 300D.
  • Page 44: Licensing

    Master) server. Port 80 (IMPULSE 300D web Port client) is the default. 4.3.7 Licensing Certain features of the IMPULSE 300D require licenses in order to be functional. The interface displays all licenses available as well as the following status: • License Locked or Unlocked •...
  • Page 45: Date/Time

    Impulse 300D – User Manual 4.3.8 Date/Time The IMPULSE 300D can be set to synchronize with an NTP server or a manual date and time can be defined by the user. Click the button to configure the date and time. These values are used to timestamp entries in the Alarm and Event logs under the Reporting tab.
  • Page 46: Updating The Impulse 300D

    Updates to the IMPULSE 300D are performed through the web interface. A software update file is provided by Sencore and then uploaded to the unit. Once uploaded, the software update is applied to the unit. To upload software updates to the unit click on the button.
  • Page 47 4.3.9.2 Rollback Software Updates The IMPULSE 300D is capable of reverting back to a previous version of software using the Rollback feature. The IMPULSE 300D maintains two separate software images; one is the most current version of software with all current settings and the other is the previous version of software with all settings.
  • Page 48: Reboot Unit

    Impulse 300D – User Manual 4.3.10 Reboot Unit The IMPULSE 300D can be rebooted from the web interface. In order to perform a reboot click the button. The IMPULSE 300D will prompt the user to confirm the reboot. Once the reboot is complete the login screen will appear allowing the web interface to be logged into.
  • Page 49: Reporting Panel

    Impulse 300D – User Manual Reporting Panel tab in the IMPULSE 300D contains logs for active alarms currently affecting the unit and an event log. The active alarms are updated periodically in order to reflect the real-time state of the unit. Once an error is cleared it will be cleared from the active alarms window.
  • Page 50: Active Alarms

    Impulse 300D – User Manual 4.4.1 Active Alarms Clicking on the button displays the Active Alarms menu. This list displays all of the active alarms currently affecting the unit. There are four columns in the log that display different types of information.
  • Page 51: Event Logs

    Event Log menu. This list displays all of the events and alarms that have affected the unit. The IMPULSE 300D stores up to 2000 events worth of logs. The logs can be cleared manually by clicking the button.
  • Page 52: Configuring The Logs

    4.4.3 Configuring the Logs The IMPULSE 300D allows the user to configure alarms and events. Events and alarms can be hidden, set to send SNMP traps or close a relay when active. In order to configure these options click the...
  • Page 53 Impulse 300D – User Manual the drop down box the icon will displayed in the event log. If Error is selected the icon will be displayed in the event log. Alarm This column is only available in the tab This option allows the user to enable or disable this alarm in the Active Alarms log.
  • Page 54: About Panel

    Impulse 300D – User Manual About Panel Under the tab, there are no user definable parameters but there is information about software versions currently installed, which licenses are installed, how to contact Sencore, and third party software information. Page 54 (67)
  • Page 55: Section 5 Appendices

    Impulse 300D – User Manual Section 5 Appendices Introduction This section includes the following appendices: – Acronyms and Glossary ............ 56 Appendix A – Error and Event List ............59 Appendix B – Specifications ..............61 Appendix C – Open Source Software ............64 Appendix D –...
  • Page 56: Appendix A - Acronyms And Glossary

    Impulse 300D – User Manual Appendix A – Acronyms and Glossary 8VSB: Vestigial sideband modulation with 8 discrete amplitude levels. 16VSB: Vestigial sideband modulation with 16 discrete amplitude levels. AAC: Advanced Audio Coding AC-3: Also known as Dolby Digital AES: Audio Engineering Society...
  • Page 57 Impulse 300D – User Manual High level: A range of allowed picture parameters defined by the MPEG-2 video coding specification which corresponds to high definition television. I/O: Input/Output IP: Internet Protocol Kbps: 1000 bit per second LED: Light Emitting Diode...
  • Page 58 Impulse 300D – User Manual RGBHV: Red, Green, Blue, Horizontal, Vertical RO: Read Only RPM: Revolutions Per Minute RRT: Rating Region Table RS-232: Recommended Standard. A standard for serial binary data interconnection. RU: Rack Unit RW: Read/Write SD: Standard Definition...
  • Page 59: Appendix B - Error And Event List

    Impulse 300D – User Manual Appendix B – Error and Event List Error Description Ac3 Audio Unsupported Without AC3 license and audio type is AC3. Audio Not Decoding Audio is corrupted in incoming stream or format is not supported. Date/Time Chaned The Date/Time setting of the system was changed.
  • Page 60 TS Sync Loss Error The system has detected the loss of sync in the transport stream. Transport Stream Not The IMPULSE 300D has detected that the transport stream from Present the active input is no longer present. UHD Video Unsupported Without UHD4K decoding license and video type is UHD4K.
  • Page 61: Appendix C - Specifications

    Impulse 300D – User Manual Appendix C – Specifications IMPULSE 300D – Output Interfaces Interfaces – 1x 75Ω BNC SDI SD/HD-SDI/3G-SDI: SMPTE 259M SMPTE 292M SMPTE 424M Digital Video: 1x HDMI Type A Connector with positive screw retention Supported Version: 1x 75Ω...
  • Page 62 Impulse 300D – User Manual AVS2 Main-10bit Profile@ L 8.2.6 Resolutions: 2160p@23.98, 24, 25, 29.97, 30, 50, 60 1080p@23.98,24,25, 29.97, 30, 50, 59.94, 60 1080i@25, 29.97, 30 720p@ 50, 59.94, 60 576i@25 480i@ 29.97 Automatic or manual (4:3 or 16:9)
  • Page 63 Impulse 300D – User Manual Operation Modes 1 RU, 1.72” (44mm) Height: 1/3 RU, 5.69” (144.5mm) Width: 7.5” (190.5mm) Depth: Weight: 1.3 lbs (0.6kg) Power: 100-240 VAC 50/60 Hz Power Consumption: Max. 9W Supplies: 1x AC Internal Connector: IEC 320 C14...
  • Page 64: Appendix D - Open Source Software

    Impulse 300D – User Manual Appendix D – Open Source Software The IMPULSE 300D includes: Package Version License Copyright amibios_dmi 75dce7b GPL Version 2, Claudio Matsuoka June 1991 BusyBox 1.20.1 GPL Version 2, Erik Anderson, et. al. June 1991 Dropbear 2016.74...
  • Page 65 Impulse 300D – User Manual PCRE 8.30 1997-2012 University of Cambridge, 2007-2008 POPT 1.14 1998 Red Hat Software Pureftpd 1.0.46 Frank Denis gDecoder 12.0.4 2000-2012 Seungyoung samba 4.7.0 GPL Version 3, 29 Andrew Tridgekk, et al. June 07 Jan Kneschke, Stefan Spawn-FCGI 1.6.3...
  • Page 66: Appendix E - Warranty

    Once an RMA number has been issued, the unit needs to be packaged and shipped back to Sencore. It’s best to use the original box and packaging for the product but if this not available, check with the customer service representative for the proper packaging instructions.
  • Page 67 Sencore Inc. 3200 Sencore Drive Sioux Falls, SD 57107 USA www.sencore.com Copyright © 2021 Sencore Inc. 1.605.978.4600...

Table of Contents