Richmond GTR500 User Manual

Swing gate opener / control system with limit switch and led indicator
Hide thumbs Also See for GTR500:

Advertisement

Quick Links

GTR500 & GTR501
SWING GATE OPENER
WITH LIMIT SWITCH AND LED INDICATOR
User Manual

Advertisement

Table of Contents
loading

Summary of Contents for Richmond GTR500

  • Page 1 GTR500 & GTR501 SWING GATE OPENER WITH LIMIT SWITCH AND LED INDICATOR User Manual...
  • Page 3: Table Of Contents

    Index PART A PART B Gate Motor and GTR500 & GTR501 & GTR502 & GTR503 Associated Parts Control System User Manual General Safety Precaution Control Box Installation Installation Wiring Connection A. Standard Installation Motor Connection B. Dimension Chart A. Motor with Limit Switch + LED Indicator C.
  • Page 4: Part A

    PART A: Gate Motor and Associated Parts...
  • Page 5: General Safety Precaution

    General Precaution: WARNING : This user manual is only for qualified technicians who is specialized in installations and automations. (1) All installations, electrical connections, adjustments and testing must be performed only after reading and understanding of all instructions carefully. (2) Before carrying out any installation or maintenance operation, disconnect the electrical power supply by turning off the magneto thermic switch connected upstream and apply the hazard area notice required by applicable regulations (3) Make sure the existing structure is up to standard in terms of strength and stability...
  • Page 6: Dimension Chart

    **Please make sure “B” and “A” are similar or the same in value that the leaves can be operated smoothly, also to reduce the burden of the motor. GTR500 & GTR501 dimension chart 120 130 140 150 160 170 180 >120°...
  • Page 7: Motor Fixing

    Motor Fixing Assemble the rear bracket and fix it on the pillar. Remove the wire cover and fix the rear bracket with the pin. Release the gate opener and place the pin into the fitting position no.1 and no. 2 no.1 no.2 Make sure the gate openers are mounted in horizontal position especially in those positions.
  • Page 8 Wire connection_Open inward Left Motor Right Motor Motor+ Motor+ Motor- Motor- Limit1 Limit1 Limit2 Limit2 White Yellow Black Green Blue White Yellow Black Green Blue Limit 1/3 Limit 2/4 Limit 1/3 Limit 2/4 Lmt1 Lmt2 Lmt3 Lmt4 Terminals of the CB19 control panel Wire connection_Open Outward Left Motor Right Motor...
  • Page 9: Led Indicator Reaction

    Emergency Release In case of power failure, push the lid of release chamber and move forward. Insert the key and turn clockwise to unlock, then turn around the knob to release. To restore the automation, simply reverse the above procedures. Step1.
  • Page 10: Technical Features

    Technical Features : Technical Feature: GTR500 & GTR501 Max gate length Max gate weight 350kg Power Supply 110V/230Vac (50-60Hz) Motor Power Supply 24Vdc Gear type Worm gear Peak Thrust 3,500N Normal Thrust 3,000N Operation Stroke 350mm Piston extension 25.5mm/sec Opening time <14 sec...
  • Page 11: Limit Switch Adjustment

    Limit switch adjustment 1. Remove the screw on the anti-shaking ring 2. Turn the anti-shaking ring 4. Adjust two Knobs to set the open and close position 3. Remove the upper-cover of the outer tube and reveal two Knobs of the front and rear limit switch Opening position: 1.
  • Page 12: Part B

    PART B: GTR500 & GTR501 GTR502 & GTR503 Control System User Manual Software Version: PS21068B Transformer MOV1 CONTROL BOX DOWN RF-LEARN...
  • Page 13: Control Box Installation

    Control Box Installation 1. Decide the installation position of control box first, it is suggested to be installed near the gate and should be protected from possible damage. Be aware of the motor cable length before deciding the installation position. 2.
  • Page 14: Motor Connection

    MOV1 Motor Connection Transformer A Motor with Limit Switch + LED Indicator LED2 LED4 LED3 DOWN 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 RF-LEARN Lit+ Lit- Lat+ DKey SKey Ph1 PhVcc PhVcc Lat-...
  • Page 15: Wi-Fi Device (Sold Separately)

    Wi-fi Device (Sold Separately) Functions of Buttons and Terminals LED Display P button: Wi-Fi Paring: Press 1 sec Default Setting: Press 3 sec Ports • LED description: Blue: LED will be flashing during WIFI pairing, and be ON when completed. Green: LED will be flashing if WB-001 receives signal from APP.
  • Page 16: Accessories Photocells (Sold Separately)

    Accessories Photocells (Sold Separately) The safety photocells are security devices for control automatic gates. Consist of one transmitter and one receiver based in waterproof covers; it is triggered while breaking the path of the beams. SPECIFICATION: Detection Method Through Beam Sensing Range MAX~15m Input Voltage...
  • Page 17: Get Started

    Get Started Note: (A) Remote memorizing must be done before system learning. (B) Verifying the GATE CONDITION. 1) Release the gear with the release key and move the gate to the middle so the gate can move in both opening and closing directions;...
  • Page 18: Step 2: System Learning

    Step 2: System Learning Step1: Press and hold SET & DOWN buttons for 3 secs till the LED shows “LEA”. Within 20 secs, press the "open-stop- close-stop" button on the remote or SET button on the control board. Then the motor runs the system learning procedure automatically.
  • Page 19: Gate-Moving Logic

    Gate-moving Logic (A) In gate-opening phase: The gates stop if the transmitter/push button/key selector is activated, and close when the transmitter/push button/key selector is reactivated. (B) In gate-closing phase: The gates stop if the transmitter/push button/key selector is activated, and open when the transmitter/push button/key selector is reactivated.
  • Page 20: Parameter Parameter Learning

    Lit+ Lit- Lat+ Lat- Lmt1 Lmt2 Lmt3 Lmt4 DKey SKey Ph1 PhVcc PhVcc Parameter Parameter Learning Push Push Push DOWN DOWN DOWN Press "SET" for 3 secs to get into the Press "UP" or "DOWN" to change Press "SET" button again to get program setting display from F1 into the sub-setting setting items from F1 to FW.
  • Page 21 LED1 LED1 LED1 LED Display Definition Parameter Table Description LED2 LED2 LED2 LED3 LED3 LED3 20% of full speed 1. The factory setting is "F73". Deceleration Speed for Opening 30% of full speed 40% of full speed (Default) 50% of full speed 20% of full speed 1.
  • Page 22 LED Display Definition Parameter Table Description LED Display Definition Parameter Table Description 1. Please see P.19 photocell adjustment for photocell Mode 1 (Default) Safety Device Function Mode logic Mode 2 2. The factory setting is "FE1". Mode 3 Mode 4 Pedestrian Mode Function OFF 1.
  • Page 23: Photocell Logic

    LED Display Definition Parameter Table Description Par ar Description D Key Function (PCB Terminal) PB Function: 1. The factory setting is "FT1" 2. Fire Alarm Mode: Open-Stop-Close-Stop (Default) * Terminal Detect NO Open ONLY - normal operation LED Display * Terminal Detect NC Pedestrian Mode - Open the gate and lock all the functions before Close ONLY...
  • Page 24: Technical Specification

    Open Only Device (Vehicle detector) Position of Gate When safety devices are activated Type of Safety Device Photocell-CLOSE Opening Device FULLY CLOSED Open No effect FULLY OPENED Reload automatic closing time STOP DURING MOVING Reload automatic closing time Open CLOSING Open Open OPENING...
  • Page 25: Trouble Shooting

    Trouble Shooting Issue: Solution: Parts to look at: No power on the - Power to the transformer is on and the connector block from the AC power lead to the transformer - Fuse board. and to the control board is wired correctly. - Transformer power - At the control board check the transformer white connector blocks are correctly - Loose wires...
  • Page 26: Technical Support

    NZ: 0800 61 71 81 International: +613 9551 2233 Richmond Wheel & Castor Co. declines all responsibility for any consequences resulting from improper use of the product, or use which is different from the expected and specified in the present documentation.

This manual is also suitable for:

Gtr501Gtr502

Table of Contents