Gate-moving Logic

(A) In gate-opening phase: The gates stop if the transmitter/push button/key selector is activated, and close when
the transmitter/push button/key selector is reactivated.
(B) In gate-closing phase: The gates stop if the transmitter/push button/key selector is activated, and open when
the transmitter/push button/key selector is reactivated.
(C) In gate-opening or gate-closing phase: For safety purpose, the gates stop if encountering obstacles.

Checking the Gate Movement

1). Release the gear with the release key and move the gate to the middle so that it can move in both
opening and closing directions; then lock the gear.
LED1
2). Operate the gate to opened and closed position several times, and make sure
LED2
switch at least 2~3 centimeters before the mechanical stop.
LED3

LED Indication

L L ED2
ED2 D Key/S Key Key selector, or the push button is activated, LED2 will be on.
L L ED4
ED4
Ph1
LED4
will be on when Ph1 are triggered.
L L ED3
ED3
Ph2
LED3
will be on when Ph2 are triggered.
CO
ON
OFF
J4
Lit+

Function Of The LED Display

LED Display
Programmable Functions
[LEA] means motor into the system learning
mode, do not interrupt during this procedure.
[D-G] means motor completed the learning
procedure for dual gate installation.
[S-G] means motor completed the learning
procedure for single gate installation.
[N-L] means system learning failed.
The memory of the system is all deleted/cleaned
by press and hold the UP + SET+ DOWN button
together for 5s and the panel will be back to
default settings
When the gate is opening, the LED Display
show 'OPN' for 2s and then change to Amp
current indication
PART B: Control System User Manual
K1
K2
K3
-
+
-
+
-
+
NC
NO
NC
NO
NC
NO
CO
CO
CO
J5
7
8
10 11 12 13 14 15 16 17 18
1 1 1 1 1 1 1 1
5
6
9
2
3
4
Lit-
Lat+ Lat-
M1+ M1-
M2+ M2-
5V
S1
-
+
1
NC
NO
CO
J3
19
19
19
19
19
19
19
19
20 21 22 23 24 25 26
S2
GND Lmt1
Lmt2
GND
Lmt3 Lmt4
GND
DKey
SKey
LED Display
the gates reaches the limit
J7
ANT
LED2
LED4 LED3
GND
J8
GND
Ph1 PhVcc
GND
Ph2 PhVcc
Programmable Functions
When the gate is stopped, the LED Display show
'STP' until next commend has been made, after
10s no further movement, the LED turns to OFF
When the gate is closing, the LED Display show
'CLS' for 2s and then change to Amp current
indication
LED display shows "S01" means the panel did not
detected the M1+/M1 and M2+/M2 both been
connected before the system learning procedure,
check for motor wire connection, for dual gate
system
LED display shows "S02" means the panel did not
detected the M1+/M1 but detected M2+/M2 been
connected, notice the installer to check the motor
wire connection, if this is single gate system,
motor wire should connect to M1+/M1 not on
M2+/M2
LED display show "S03" means same button on
the remote has been identified for more than 2
functions