FE3
Open Only Device (Vehicle detector)
Position of Gate
Type of Safety Device
FULLY CLOSED
FULLY OPENED
STOP DURING MOVING
CLOSING
OPENING
FE4
Double photocell set up
Position of Gate
Type of Safety Device
FULLY CLOSED
FULLY OPENED
STOP DURING MOVING
Solution:
CLOSING
6. T
echnical Features
OPENING
Technical Specification
Main power supply
Back-up battery
Receiver board
Installation
Operating Temperature
Dimension
20
When safety devices are activated
PH1
Opening Device
Open
Reload automatic closing time
Open
Open
No effect
When safety devices are activated
PH1
Photocell-OPEN/CLOSE
No effect
Reload automatic closing time
Reload automatic closing time
Open
No effect
230Vac/110Vac, 50Hz/60Hz
2pcs of batteries for emergency operation, 2.2A each (Sold Separately)
433.92MHz; 200 transmitters memory
Wall mounted vertically
-20℃~+50℃
275mm * 195mm * 102mm
PH2
Photocell-CLOSE
No effect
Reload automatic closing time
Open
No effect
PH2
Photocell-OPEN/CLOSE
No effect
No effect
Open
No effect
PART B: Control System User Manual