Get Started

Note:
(A) Remote memorizing must be done before system learning.
(B) Verifying the GATE CONDITION.
1) Release the gear with the release key and move the gate to the middle so the gate can move in both opening
and closing directions; then lock the gear.
2) Operate the gate to opened and closed position several times and make sure the gates touches the limit switch at least
2~3 cm before the mechanical stop.

Step 1: Remote Learning

A. Learning
1. Press "RF Learn" button for 3 seconds, and the LED display shows "CS". Then press any desired button on the remote;
the LED display will blink "CS" three times and stay on. After 7 seconds without any new remote learn then the LED will be
off The transmitter learning is completed.
(figure 1)
B. Remote Learning without Control Board:
(1) Press the A & B buttons on the OLD remote and hold down for at least 5s, then release them. (the alarm will buzz 2
secs, and LED will display "CS")
(2) Press any desired button on the NEW remote within 10 seconds (the alarm will buzz 3 times, LED blinks "CS" for 3
times)
Old Remote
A
B
C. Deleting All Memory of All Remotes:
With this operation all the memorized transmitters will be deleted.
(1) Press and hold down RF-LEARN button (Figure 4) on the control board for 10 seconds.
(2) Wait until the LED display shows "CC". All memory is deleted.
RF-Learn
10 Sec
PART B: Control System User Manual
(figure 1)
UP
SET
DOWN
RF-LEARN
A
3 Seconds
(figure 4)
RF-Learn
3 Sec
New Remote
B
Press any button
in 10 Seconds
CC
DONE
New Remote
A
B
(Press any
desired button)
CS
Blink 3 times
13