Solar Swing Gate Opener User’s Manual For Gate Kits: GTR062 Single Solar Swing Gate Kit GTR078 Double Solar Swing Gate Kit Please read and follow all warnings and instructions before installation and use. • The gate opener must be powered by 2 PCS 12VDC/12Ah batteries (connected in •...
gate to operate the controls. Controls are to be placed at least Safety Installation Information 6’ (1.8m) from any part of the moving gate. READ and FOLLOW all instruction. The gate opener is intended for use with Class I vehicular swing gates.
Features: Built in adjustable auto-close (0-100 seconds) · Soft start and soft stop · · Built in max. Motor running time (MRT) for Emergency release key in case of power failure · multiple safety protection (40 seconds) Fast selecting push/pull to open ·...
Preparation for Installation There are two installation types for the gate opener, Pull-to-Open and Push-to-Open. In the Push-to-Open installation, gate opens out from the property. A Push-To-Open Bracket (PSO part) is required to be used for each gate. NOTE: Ensure the gate does not open into public areas. The gate opener is mounted to the gate and to the gate post.
Page 6
Push-to-Open Installation — Gate in Closed position (Moving-Rod is retracted) 1. Insert the M10 x 30 bolt through the center hole of the post bracket and post pivot bracket as shown. Place a ¢10 washer , ¢10 lock washer and M10 nut on the bottom of the bolt and hand tighten. 2.
Page 7
3. Open the release hole plug on the top of the gate opener, insert the release key, and turn the key 90° clockwise. This releases the motor and allows the push-pull rod to be manually extended and retracted. To restore normal operation, turn the key 90° counterclockwise. 4.
Page 8
5. Make sure that there is a minimum clearance of 2.5cm between the gate and the opener and that the opener and the Post Pivot Bracket are not binding in both the gate-open and gate-closed positions. If there is not at least 2.5cm of clearance or if the opener and the Post Pivot Bracket are binding, rotate the Post Pivot Bracket and/or move the Post Bracket Assembly to obtain the minimum clearance and eliminate the binding.
Page 9
6. Sign the bolt-hole point on the gate bracket and gate. Do this by placing a punch or a sign in the middle of each bolt slot on the post bracket assemblies and the gate bracket. It allows slight adjustments to the post bracket. Then remove the post bracket and gate bracket by taking off the C-clamps.
12. Open the release hole plug on the top of the gate opener, insert the release key, and turn the key 90° counterclockwise. This restores normal operation. NOTE: The setting of the PULL/PUSH TO OPEN of the control board should be in accordance with the installation.
Page 11
1. Use the batteries as the power source and only use the solar panel to charge the batteries If you only use the solar panel to charge the batteries, please note the power of the solar panel should be at least 30W x 24V.
Page 13
Cut/remove existing Plug & Play fitting from motor cable. Strip wires to expose the coloured wires. 1. Actuator 1 (Master gate, open first & close last) Insert the stripped cable wires into the appropriate terminals on the opener terminals block. The red wire should be inserted into the “+MOTOR1”...
Page 14
9. Exit Wand (optional) The BLACK wire of the exit wand should be connected into the “#5” terminal. The BLUE wire of the exit wand should be connected into the “#6” terminal. The RED wire of the exit wand should be connected into the “#11” terminal. The GREEN wire of the exit wand should be connected into the “#12”...
How to Program the Remote to the Opener You must program the remote to the opener before operating. You can follow the below steps to program the remote to the opener. Press and release the CODE SW button, the CODE LED will be ON, then press the key in the remote twice in 4 seconds, the CODE LED will flash for 3 seconds and then to OFF.
How to use the remote to operate your gate opener Each remote has four buttons, from top to bottom are separately A, B, C and D. You may use this remote to operate as many as 4 sets our swing gate opener or 1 set our sliding gate opener and 2 sets our swing gate opener.
Page 17
1. DIP Switches The DIP switches are used to select pull/push to open, enable/disable auto close function, enable/disable open interval between the master and slave gate opener, enable/disable close interval between the master and slave gate opener and enable/disable photo beam function. DIP Switch #1: Select push/pull to open If the gate opens into the property (pull to open), the DIP Switch is set to OFF (factory default setting).
Page 18
2. Potentiometers There are 5 potentiometers located in the control board. They are used to adjust soft stop period, auto-close time, open interval and close interval time between master gate opener and slave gate opener, and the stall force. Potentiometer A is used to adjust the soft stop period of the gate opener. Turn the potentiometer clockwise to increase the soft stop period, and turn it counter-clockwise to decrease the soft stop period.
Page 19
Status of LED(s) & Trouble Shooting Status of LED(s) Status of gate Possible opener Solution(s) CODE LED POWER LED FULL LED Normal (Voltage of Flash(1 Blink every Standby battery second) normal) Flash(1 Blink every Flash(1 Blink every Flash(1 Blink every Running Normal second )
Page 20
Flash quickly for 3 Voltage of the Both of the gates do seconds and then battery is low, wait not move when back to flash the battery to be operating slowly(1 Blink every charged. second) Ensure the Flash quickly for 3 photo beam is not Both of the gates do Flash quickly for 3...