Richmond GTR500 User Manual page 22

Swing gate opener / control system with limit switch and led indicator
Hide thumbs Also See for GTR500:
Table of Contents

Advertisement

LED Display
Definition
LED Display
Definition
FE
Safety Device Function Mode
Pedestrian Mode
FF
FG
Flashing Light
FH
Photocell 1 Activation
FI
Photocell 2 Activation
FJ
Alarm Buzzer
FK
Electric Latch Mode
LED Direction
FL
FN
Over Current Reverses Time
when Close
FO
A Button Function (Remote)
FP
B Button Function (Remote)
FR
C Button Function (Remote)
FS
D Button Function (Remote)
18
Parameter
Table
Parameter
Table
FE1
Mode 1 (Default)
FE2
Mode 2
FE3
Mode 3
FE4
Mode 4
FF0
Function OFF
FF1
Function ON (Default)
FG0
Function OFF (Default)
FG1
Function ON
FH0
Function OFF (Default)
Function ON
FH1
FI0
Function OFF (Default)
FI1
Function ON
Function OFF (Default)
FJ0
FJ1
Function ON
FK1
Standard Gate Opening (Default)
FK2
Release Gate Tension before
Opening (Gate Reversing for 0.25s)
FL0
When Terminal Block is at bottom
(for swing gate motor )
FL1
When Terminal Block is at top
(for articulated-arm motor
>> Default)
FN0
Function OFF (Default)
FN1
0.1 sec
FN2
0.2 sec
FN3
0.3 sec
0.4 sec
FN4
FN5
0.5 sec
FN6
0.6 sec
FO0
Function OFF
FO1
Open-Stop-Close-Stop (Default)
FO2
Pedestrian Mode
FO3
Turn auto-closing OFF via remote
Open ONLY
FO4
FP0
Function OFF
FP1
Open-Stop-Close-Stop
Pedestrian Mode (Default)
FP2
FP3
Turn auto-closing OFF via remote
FP4
Open ONLY
Function OFF (Default)
FR0
FR1
Open-Stop-Close-Stop
Pedestrian Mode
FR2
FR3
Turn auto-closing OFF via remote
FR4
Open ONLY
Function OFF (Default)
FS0
Open-Stop-Close-Stop
FS1
Pedestrian Mode
FS2
Turn auto-closing OFF via remote
FS3
Open ONLY
FS4
Description
Description
1. Please see P.19 photocell adjustment for photocell
logic
2. The factory setting is "FE1".
1. The factory setting is "FF1".
2. When it's set "FF0":
there won't be any response while pressing
remotes & D/Skey terminals
3. When it's set "FF1":
*single gate installation >> master gate fully opens
*dual gate installation >> master gate opens 50%
1. When function FG1, the light will flash for 3 seconds
before the gate operates. If set OFF, the flash light will
operate with motor at the same time.
2. The factory setting is "FG0".
1. The factory setting is "FH0".
1. The factory setting is "FI0".
1. The factory setting is "FJ0".
1. If the fun c tion is FK2, the motor will be reversed for
0.25 sec. to release the tension.
2. The factory setting i s "FK1".
1. The factory setting is "FL1".
The UP(▲) and Down(▼) buttons will switch according to
the parameter setting.
When FL0, bu tton SW5 stand s for ▲(UP) , and button
SW3 stand s for ▼(DOW N).
When FL1, bu tton SW3 stand s for ▲(UP) , a nd button
SW5 stand s for ▼(DOW N)
1. The factory setting is "FN0"
1. The factory setting is "FO1"
1. The factory setting is "FP2"
1. The factory setting is "FR0"
1. The factory setting is "FS0"
PART B: Control System User Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gtr501Gtr502

Table of Contents