Index G220 Operating Instructions And Maintenance Instructions page 78

Table of Contents

Advertisement

74
13.
Auto_Arbeitsraumtuer_G220_6
X
400 mm measuring range
Conditions to measure the belt tension. Open the work area door until there is a
400 mm clearance between the actuator (2) on the belt and the deflection
pulley/belt tensioner (3). (see examples of Auto_Arbeitsraumtuer_G220_6 + 5)
14.
Auto_Arbeitsraumtuer_G220_5
1
Drive
2
Driver
3
Belt tensioner
M
Measuring point for frequency meter
Adjust belt tension. Using a frequency meter and the belt tensioner (3) , the belt
tension can now be set to 100 Hz at the marked poin t M.
Maintenance Summary - 4.000 Operating hours
Maintenance Instructions
G220
DIE017EN - 05.06.2019

Advertisement

Table of Contents
loading

This manual is also suitable for:

C200-sl

Table of Contents