Error messages

Transmission errors

When an operating anomaly appears in the hydraulic transmission the symbol on the right is displayed on the CANcockpit.
1. Alarm connected to the machine transmission (SD).
2. Error code of alarm in progress.
If an operating fault appears in the transmission, an acoustic alarm
placed near the operator's seat sounds and the message fig.1 is
displayed in the CANcockpit.
• Press the pushbutton fig. A to display the error code [SD] in
progress fig.2.
Example
Err SD 83 CAN bus communication error
÷
NOTE! The error code automatically disappears when the operating anomaly has been resolved.
Table of SD error codes
Error
codes
001
Low battery voltage
002
Low battery voltage
003
12V sensor low supply voltage
004
12V sensor high supply voltage
005
5V sensor low supply voltage
006
5V sensor high supply voltage
007
Stack overflow
008
E2prom memory error
009
FLASH memory error
010
RS232 memory error
011
CAN bus connection error
012
Current return protection
020 to 045
Internal system error
051
MAF loading error
052
Inconsistent key
053
Inconsistent MAF
054
Inconsistent input/output
055
Error in sensitive parameter
056
SDPHASE code error
057
Checksum error
058
Min/Max error in parameter
DESCRIPTION
A
Error
codes
070
Loop error
071
PWM2 current loop error
074
Loop error pump 1
080
Brake pressure sensor signal out of range
083
CAN bus communication error: signal not received
084
High pressure sensor signal out of range
092
Joystick sensor error
097
Analogue mode selector sensor error
100
Joystick limitation control error
102
Transmission temperature too high error
200
Offroad SD: high battery voltage
201
Offroad SD: low battery voltage
202
Offroad SD: 12V supply voltage sensor out of range
7 - Troubleshooting
!