7 - Fault Finding

Mechanical Problems

Emergency Operation - Hydraulics

In case of power failure, the damper control can be operated as follows:
1. Remove plastic cover (A) from valve (B).
2. Turn valve (B) inwards.

Emergency Operation - Liquid System

In case of power failure, it is possible to operate all functions of the
operating unit manually. First disconnect the multi-plug from the
control box. Now manually turn the emergency control knobs on the
distribution valves.
The problem may be due to a blown fuse. A fuse is placed inside the
control box. Fuse type: Thermo.

Emergency Operation - EasyClean Filter

If difficulties with opening the filter and closing the built-in valve occur,
it can be emergency handled by using a 13 mm wrench on the key
profile (A).
Also the filter can be drained before filter element at the drain plug (B).
±
WARNING! Always wear protective clothing and gloves before
opening the filter!