Mitsubishi Electric E70 Series Connection Manual page 45

Hide thumbs Also See for E70 Series:
Table of Contents

Advertisement

MITSUBISHI CNC
2 General Specifications
(18) LED
Name
Name
24VDCIN
24VDC input check
DCOUT
Internal output voltage check Not lit
12VDC output voltage check
LCDON
for backlight driver
External emergency stop
PSEMG
status display
WDER
System error display
BATALM
Battery voltage drop
20
 
Function
At fault
Not lit
Not lit
Lit (Red)
Lit (Red)
Lit (Red)
Conditions
(1) Failure of 24VDC input
(2) Fuse is disconnected near DCIN connector
(1) Failure of internal voltage output in control unit
(2) Short circuit of 5VDC output on CG71 or ENC
(1) Failure of 12VDC output in control unit
(2) 24VDC input voltage is +20V or less
External emergency stop signal has inputted
(1) Failure of control unit
(2) SRAM data is broken
Battery voltage has dropped to 2.7V or less