Using Booster Batteries—24-Volt System
Before boost starting, machine must be properly shut
down to prevent unexpected machine movement when
engine starts.
CAUTION: An explosive gas is produced while
batteries are in use or being charged. Keep
flames or sparks away from the battery area.
Make sure the batteries are charged in a well
ventilated area.
IMPORTANT: The machine electrical system is a
24-volt negative (-) ground. Connect two
12-volt booster batteries together as
shown for 24-volts.
1. Connect one end of the positive cable to the positive
terminal of the machine batteries (A) and the other end
to the positive terminal of the booster batteries (B).
2. Connect one end of the negative cable to the negative
terminal of the booster batteries. Connect the other
end of the negative cable to the machine frame as far
away from the machine batteries as possible.
3. Start engine.
4. Immediately after starting engine disconnect the end of
the negative cable from the machine frame. Then
disconnect the other end of the negative cable from the
negative terminal of the booster batteries.
5. Disconnect positive cable from booster batteries and
machine batteries.