Maintenance-Every 1000 Hours; Change Swing Gearbox Oil - Hitachi Zaxis 200LC Operator's Manual

Forester
Hide thumbs Also See for Zaxis 200LC:
Table of Contents

Advertisement

Maintenance—Every 1000 Hours

Change Swing Gearbox Oil

Zaxis 200LC—Specification
Swing Gearbox—Oil Capacity
...............................................
Zaxis 250—Specification
Swing Gearbox—Oil Capacity
...............................................
Zaxis 350—Specification
Swing Gearbox—Oil Capacity
...........................................
Zaxis 350—Specification
Optional 2nd Swing Gearbox—Oil
Capacity
.................................................................................
1. Remove plug mounted on end of drain pipe to drain oil
into a container. Dispose of waste oil properly.
2. Install plug.
3. Remove filler cap (2) and add oil. (See Section 3-1.)
4. Install filler cap.
5. Check oil level on dipstick (1).
1—Dipstick
2—Filler Cap
4.7 L (5.0 qt)
7.6 L (8.0 qt)
14.0 L (15.0 qt)
2.6 L (2.8 qt)
3-10-1
Zaxis 200LC, 250
Zaxis 350
TX14740,0001F3E –19–22NOV02–1/1
081407
PN=138