Rapid traverse rate [ m / min ]
2.15

Coolant equipment

Power of the cooling lubricant pump [ W ]
Delivery volume [ L / min ]
Capacity cooling lubricant tank [ L ]
Delivery height [ meter ]
2.16

Central lubrication

Supply of lubrication points
Tank capacity
Interval of time
2.17

Environmental conditions

Temperature
Admissible relative humidity
Compressed air
Environmental conditions - storage
2.18

Emissions

Measurement in operating conditions in accordance with DIN ISO 8525 with surface areas
Measurement methods in accordance with DIN 45635.
The generation of noise emitted by the machine is 79 dB(A) on no-load running at 80% of max.
spindle speed and activated automatic feed on no-load running at 80% of the possible feed
speed, measured at a distance of one meter from the machine and at a height of 1.6m.
If the milling machine is installed in an area where various machines are in operation, the noise
exposure (immission) on the operator of the milling machine at the working place may exceed
80 dB(A).
INFORMATION
This numerical value was measured on a new machine under the operating conditions specified
by the manufacturer. The noise behaviour of the machine might change depending on the age
and wear of the machine.
Furthermore, the noise emission also depends on production engineering factors, e.g. speed,
material and clamping conditions.
INFORMATION
The specified numerical value represents the emission level and does not necessarily a safe
working level.
Though there is a dependency between the degree of the noise emission and the degree of the
noise disturbance it is not possible to use it reliably to determine if further precaution measures
are required or not.
The following factors influence the actual degree of the noise exposure of the operator:
GB
MZ4 │MZ4V
Page 22
Feed axis
Original operating instructions
1
X │
Z
│ Y
95
25
42
3
automatic
2
infinitely adjustable
19 - 21 °C (for an optimum milling result)
permissible range + 10° to + 35°C
5...90 % no condensation
30% to 90% at 35°C
90 % at 21°C
700...1060 hPa
5 - 45 °C