2.9

Environmental conditions - operation

Temperature
Admissible relative humidity
Compressed air
2.10

Environmental conditions - storage

Temperature
2.11

Emissions

The noise emission of the CNC machine is 80 dB(A).
If the CNC machine is installed in an area where various machines are in operation, the noise
exposure (immission) on the operator of the drilling machine at the working place may exceed
80 dB(A).
INFORMATION
This numerical value was measured on a new machine under the operating conditions specified
by the manufacturer. The noise behaviour of the machine might change depending on the age
and wear of the machine.
Furthermore, the noise emission also depends on production engineering factors, e.g. speed,
material and clamping conditions.
INFORMATION
The specified numerical value represents the emission level and does not necessarily a safe
working level.
Though there is a dependency between the degree of the noise emission and the degree of the
noise disturbance it is not possible to use it reliably to determine if further precaution measures
are required or not.
The following factors influence the actual degree of the noise exposure of the operator:
Characteristics of the working area, e.g. size or damping behaviour,
other noise sources, e.g. the number of machines,
other processes taking place in proximity and the period of time, during which the operator
is exposed to the noise.
Furthermore, it is possible that the admissible exposure level might be different from country to
country due to national regulations.
This information about the noise emission should, however, allow the operator of the machine
to more easily evaluate the hazards and risks.
CAUTION!
Depending on the overall noise exposure and the basic threshold values, machine
operators must wear appropriate hearing protection.
We generally recommend the use of noise protection and hearing protection.
GB
F3
Page 22
19 - 21 °C (for an optimum milling result)
19 - 21 °C (for operation without malfunctions)
5...80 % no condensation
700...1060 hPa
5 - 45 °C
Original operating instructions
Technical data