CONSTRUCTION OF THE DMX TERMINATION

The termination is prepared by soldering a 120Ω 1/4 W resistor between pins 2 and 3 of the male XLR
connector, as shown in figure.

DMX ADDRESSING

In order to start controlling the product via DMX, the first step is to select a DMX address, also known
as the start channel, this is the first channel used to receive instructions from a DMX controller. If you
wish to control the product individually, it is necessary to assign a different starting address channel to
each fixture.
The number of channels occupied from the product depends on the DMX mode selected, so always
verify the DMX Mode in the MENU before start addressing.
If you assign two fixtures the same address, they will be executing the same behaviour. Selecting the
same address to multiple fixtures can be useful for diagnostic purposes and symmetrical control.
DMX addressing is limited to make it impossible to set the DMX address so high that you are left with-
out enough control channels for the product.
To set the fixture's DMX address:
1. Press MENU to open the main menu.
2. Reach the addressing menu, then select the DMX ADDRESS settings.
3. Select the address from 1 to 512 using the navigation arrows/buttons and confirm by pressing
ENTER.
4. Press Menu to exit and return to the Home screen.
ETHERNET CONNECTION
The products is provided with two 8-pin RJ-45 sockets for Ethernet input/output for a simple daisy
chain connection to the network.
The product can be controlled with ArtNet/sACN communication protocol.
Use a network cable category 5 (with four "twisted" wire pairs) and standard RJ-45 plugs.

ETHERNET OPERATION

Please refer to the section MENU STRUCTURE contained in this document for detailed informations
about the parameters of setting on the fixture (Protocol, Net, Subnet, Universe, Start Channel and IP
Address, Ethernet to DMX No/Yes).
IP addresses recommended: 002.xxx.xxx.xxx or 010.xxx.xxx.xxx.
The submask net is fixed at 255.0.0.0.

ETHERNET TO DMX OPERATIONS

Please refer to the section MENU STRUCTURE contained in this document for detailed informations
This function allow a product receiving an ethernet signal protocol to re-transmit the incoming signal
onto a wired DMX line through its onboard XLR-out connector.
• An Ethernet protocol (Artnet, sACN or others available) has to be enabled from Ethernet menu
Example: