CONNECTION OF THE DMX LINE

DMX connection employs standard XLR connectors. Use shielded pair-twisted cables with 120Ω im-
pedance and low capacity.
The following diagram shows the connection mode:
DMX Address: 1
DMX IN
DMX OUT

CONSTRUCTION OF THE DMX TERMINATION

The termination is prepared by soldering a 120Ω 1/4 W resistor between pins 2 and 3 of the male XLR
connector, as shown in figure.
10
DMX Address: 10
DMX IN
DMX OUT
DMX512 Controller
Pin1 : GND - Shield (Black)
Pin2 : - Signal (Yellow)
Pin3 : + Signal (Red)
Pin4 : Auto-addressing (White)
PROLIGHTS - ArcSpot XSVW
DMX Address: 19
DMX IN
DMX OUT
Fig. 08 - Example 9 DMX channels configuration
Example:
5 pin XLR connector
DMX Address: 28
DMX IN
DMX OUT
4
. . . . . . . . . . . .
. . . . . . . . . . . .