Generic Wiring Diagram-8-Pin Receiver And Im-T-9A Interface Module - Banner SLLE14-280 Instruction Manual

Ls safety light screen
Table of Contents

Advertisement

®
EZ-SCREEN
LS Safety Light Screen
6.5.6 Generic Wiring Diagram—8-pin Receiver and IM-T-9A Interface Module
8-pin male
M12/Euro-style
(face view)
* Installation of transient (arc) suppressors across the coils of MPCE1 and MPCE2 is recommended (see WARNING).
** Scan Code 1: not connected or connected to 0 V dc (as shown). Scan Code 2: connect to 24 V dc.
*** Other interfacing modules and solutions available. See the Banner Engineering catalog or website for more information.
Note: See the IM-T-..A module datasheet (p/n
WARNING: Use of Transient Suppressors
If transient suppressors are used, they MUST be installed across the coils of the machine control
elements. NEVER install suppressors directly across the contacts of the IM-T-..A Module. It is possible
for suppressors to fail as a short circuit. If installed directly across the contacts of the IM-T-..A Module, a
short-circuit suppressor creates an unsafe condition. Failure to follow these instructions could result in
serious injury or death.
58
Bn (Pin #1)
Gn/Ye (#7)
Bu (#6)
Bk (#5)
Wh (#4)
Scan Code **
Vi (#8)
Or (#3)
Fault Out
Or/Bk (#2)
Figure 40. Generic Wiring Diagram—IM-T-9A Interface Module (1-Channel EDM)
www.bannerengineering.com - Tel: +1.763.544.3164
+24V dc
IM-T-9A ***
S3
K2
S4
Y3
Y1
13
23
Machine
Control
33
Feedback (optional)
62822
) for complete installation instructions.
0V dc
S1
K1
S2
Y4
Y2
14
MPCE
1
*
24
MPCE
2
34
*

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sllr14-280Sllp14-280Slle14-350Sllr14-350Sllp14-350Slle14-420 ... Show all

Table of Contents