Double Move: Movl(032) - Omron CVM1D Operation Manual

Hide thumbs Also See for CVM1D:
Table of Contents

Advertisement

Data Movement Instructions

5-15-3 DOUBLE MOVE: MOVL(032)

Ladder Symbol
(032)
MOVL
Variations
j MOVL(032)
Description
S
Precautions
Flags
Example
0000
05
S
D
When the execution condition is OFF, MOVL(032) is not executed. When the ex-
ecution condition is ON, MOVL(032) copies the content of S and S+1 to D and
D+1.
S+1
Neither D nor S can be the last word in a data area because they designate the
first of two words.
Constants are input using eight digits.
Note Refer to page 101 for general precautions on operand data areas.
Content of *DM word is not BCD when set for BCD.
ER (A50003):
EQ (A50006):
Content of D and D+1 are 0 after execution.
N (A50008):
Same status as bit 15 of D+1 after execution.
When CIO 000005 is ON in the following example, the contents of A400 and
A401 are copied into D00200 and D00201, respectively.
(032)
MOVL
A400 D00200
A400
A401
D00200
D00201
Operand Data Areas
S: Source
CIO, G, A, T, C, #, DM
D: Destination
CIO, G, A, T, C, DM
D
Bit status
not changed.
Before
execution
3
7
0
0
0
1
F
9
0
0
0
0
0
0
0
0
Section 5-15
D+1
Address Instruction
00000
LD
00001
MOVL(032)
After
execution
A400
3
7
0
0
A401
0
1
F
9
D00200
3
7
0
0
D00201
0
1
F
9
Operands
000005
A400
D00200
177