STEP DEFINE and STEP START: STEP(008)/SNXT(009)
0000
SW1
01
Programming for process A
0000
SW2
02
Programming for process B
0000
SW3
03
Programming for process C
0000
SW4
04
360
The following diagram demonstrates the flow of processing and the switches
that are used for execution control.
The program for this process, shown below, utilizes the most basic type of step
programming: each step is completed by a unique SNXT(009) that starts the
next step. Each step starts when the switch that indicates the previous step has
been completed turns ON.
(009)
SNXT 012800
(008)
STEP 012800
(009)
SNXT 012801
(008)
STEP 012801
(009)
SNXT 012802
(008)
STEP 012802
(009)
SNXT 012803
(008)
STEP 012803
SW1
Process A
Loading
SW2
Process B
Part Installation
SW3
Process C
Inspection/discharge
SW4
Address Instruction
Process
A started.
00000
00001
00002
Process
A reset.
00100
Process
00101
B started.
00102
Process
B reset.
00100
Process
00101
C started.
00102
Process
C reset.
00200
00201
00202
Section 5-29
Operands
LD
000001
SNXT(009)
012800
STEP(008)
012800
Process A
LD
000002
SNXT(009)
012801
STEP(008)
012801
Process B
LD
000003
SNXT(009)
012802
STEP(008)
012802
Process C
LD
000004
SNXT(009)
012803
STEP(008)
012803