INTRODUCTION ......................21 FREEZING UNITY DUE TO A WRONG LAN NETWORK SETUP (ONLY FOR SKILL- RUN UNITY 5000 / 7000) ....................21 ETHERNET CABLED NETWORK (ONLY FOR SKILLRUN UNITY 5000 / 7000) ..21 WI-FI NETWORK REQUIREMENTS ................21 WIRELESS GUIDELINES ...................22 MAXIMUM NUMBER OF EQUIPMENT CONNECTED TO ONE ACCESS POINT ..23 INTERNET CONNECTION BANDWIDTH REQUIREMENTS (ONLY FOR SKILL- RUN UNITY 5000 / 7000) ....................23...
Page 4
RANGE OF FRAMERATE AND BITRATE OF DVB-T HD VIDEO STREAM ..33 UNITY 3.0 - VERSION (-A) STANDARD OPTIONS - USA/CANADA......33 UNITY 3.0 - VERSION (-I) STANDARD OPTIONS - JAPAN ........36 SKILLRUN CLASS REQUIREMENTS (ONLY FOR SKILLRUN UNITY 5000 / 7000) ........................39 ACKNOWLEDGEMENT AND ACCEPTANCE ...........41 LIST OF CHANGES FOR MANUAL REVISION ..........43...
Page 5
NOTES: This document contains proprietary information that is covered by copyright. All- rights reserved. No part of this document may be circulated, copied, reproduced or trans- lated into another language without the prior written consent of Technogym. Additional information may be included in the After Sales technical documents, available in the official ‘After Sales documents repository’.
SKILLRUN (DJJ) Pre-Installation Requirements Rev. 2.0 GENERAL WARNINGS This manual includes informative notes with specific meanings: DANGER: Indicates an imminently hazardous situation which, if not avoided, will re- sult in death or serious injury. This signal word is to be limited to the most extreme situations.
INSTALLATION 2.1 NETWORK DESIGN AND INSTALLATION During the network design and preparation phases, Technogym requests to be put in touch with the technicians of the company performing the work, in order to obtain and provide technical informa- tion, so that the network is installed and configured according to the required technical.
SKILLRUN (DJJ) Pre-Installation Requirements Rev. 2.0 Fig. 5 The power supply socket must be grounded . If not, a ground connection must be in- stalled by a qualified electrician before connecting the equipment to the electricity mains. The product must be grounded.If the unit malfunctions or breaks down, earthing provides a mini- mum resistance path for electric current thus reducing the risk of electric shock.
SKILLRUN (DJJ) Pre-Installation Requirements Rev. 2.0 4.5 POSITIONING OF POWER SUPPLY SOCKET AND LAYOUT OF CABLES In the SKILLRUN, It is mandatory to correctly arrange the cables (TV + LAN + power cord), pre- venting the cables from being pinched when the belt is moving and the equipment moves with a gradient.
Page 18
SKILLRUN (DJJ) Pre-Installation Requirements Rev. 2.0 ATTENTION: It is not recommended to have the power supply socket located below the Skillrun. LAYOUT 1 / 4: ATTENTION: The LAYOUT 1 is the recommended layout. Fig. 8 - Layout 1 recommended Layout 4: make sure that the cables are long enough. LAYOUT 2 / 3: It is recommended to use a sheath for cables (to be provided by the customer) that guides the bending of cables.
Page 19
SKILLRUN (DJJ) Pre-Installation Requirements Rev. 2.0 LAYOUT 5: The following figure doesn’t show a sheath for cables but Its use is recommended (to be provided by the customer). The cable must follow the following path. If this is not possible, it’s required to reverse the socket (case of American plug) (to be provided by the customer).
SKILLRUN TX 500 (equipment fitted with TX10” interface) support a wireless internet connection. In all cases, the network must be installed and configured by the customer before Technogym deliv- ers the product, in accordance with the technical specifications set out below.
SKILLRUN (DJJ) Pre-Installation Requirements Rev. 2.0 NOTE: The Protocol WPA2 Enterprise is not supported. _There must be only one dedicated Access Point / Wi-Fi router that provides the service; _ DHCP enabled; In case of professional Access Point or if the equipment is used in a public / company network (hotel, fitness facility) you must cover the following additional requirements: _Configure the Access Point to broadcast only one SSID (Service Set Identifier) needed for the equipment installation.
SKILLRUN (DJJ) Pre-Installation Requirements Rev. 2.0 5.6 MAXIMUM NUMBER OF EQUIPMENT CONNECTED TO ONE ACCESS POINT _Up to 5 devices: use a commercial Access Point. _More than 5 devices: use a professional Access Point (see the technical datasheet). For more details about Access Point, refer to the AP technical specifications. 5.7 INTERNET CONNECTION BANDWIDTH REQUIREMENTS (ONLY FOR SKILLRUN UNITY 5000 / 7000)
[1]: See “5.4 WI-FI NETWORK REQUIREMENTS” and “5.6 MAXIMUM NUMBER OF EQUIPMENT CONNECTED TO ONE ACCESS POINT”. [2]: See “5.3 ETHERNET CABLED NETWORK (ONLY FOR SKILLRUN UNITY 5000 / 7000)”. [3]: The integration of caching server optimizes performance of network and reduces the bandwidth requirements for the club.
Free access to the Internet must be guaranteed for correct use of the Mywellness Cloud services, and in particular access to the following DNS names must never be disabled. SKILLRUN UNITY 5000 / 7000 DNS Names for UNITY 3.0 Display mywellness.com...
Tab. 5 - DNS Names for SKILLRUN with TX Display (10”) NOTE: It shall be possible to download .tar packets. 5.10 PROXY (ONLY FOR SKILLRUN UNITY 5000 / 7000) This parameter MUST ALWAYS BE DISABLED, because if enabled UNITY 3.0 does not manage the Apps.
SKILLRUN (DJJ) Pre-Installation Requirements Rev. 2.0 STANDARD TV TECHNICAL SPECIFICATIONS (ONLY FOR SKILLRUN UNITY 5000 / 7000) 6.1 INTRODUCTION The data useful to antenna installers for checking the suitability of the antenna signal input to the equipment with UNITY 3.0 are detailed below.
SKILLRUN (DJJ) Pre-Installation Requirements Rev. 2.0 Fig. 15 6.2 VIRTUAL LAN UNITY 3.0 doesn’t manage the VLANs because UNITY 3.0 has only one CPU port that manages both Internet and IPTV on the same network.Therefore it’s not possible to set a VLAN network on IPTV infrastructure.
SKILLRUN (DJJ) Pre-Installation Requirements Rev. 2.0 6.4 UNITY 3.0 - VERSION (-T) STANDARD OPTIONS NOT ENCRYPTED ▪ Analog TV + FM Radio ▪ Digital TV DVB-T/ DVB-T2 (mpeg2 & H264) not encrypted ▪ Digital TV DVB-T/ DVB-T2 (HEVC) not encrypted -> (ADD-ON A0000854) ▪...
Page 32
SKILLRUN (DJJ) Pre-Installation Requirements Rev. 2.0 STANDARD (NOT ENCRYPTED) DVB-T/ DVB-T2/ DVB-C/ISDB-Tb (not Japan) ANALOG / IPTV UNITY 3.0 VERSION “-T“ Broadcast System DIGITAL TV: DVB-T/DVB-T2 (mpeg2 & H264)/ DVB-C / ISDB-Tb ANALOG TV: YES RADIO FM: YES RF INPUT: F-Type connector INPUT INPEDENCE: 75 Ohm (max nondestructive input power: 10 dBm) DVB-C...
SKILLRUN (DJJ) Pre-Installation Requirements Rev. 2.0 DVB-T2 HEVC UNITY3.0 VERSION “-T“ + UPGRADE KIT A0000854 Codecs MPEG-2, MPEG-4 H264/AVC - H.265/HEVC decoding Video Resolutions Decodes up to 720p and 1080p@50/60Hz Audio Mpeg1 (Layer I/II/III), Mpeg2(Layer I/II), Dolby D, Dolby D+, HE- AACv1, MP3 Analog TV Radio FM...
Page 34
SKILLRUN (DJJ) Pre-Installation Requirements Rev. 2.0 ▪ Pro:IDIOM : IPTV SD/HD (LAN mpeg over UDP/RTP) ENCRYPTED Pro:IDIOM -(ADD-ON A0000897) ▪ IPTV (other encryption standards): Centrally convert the signal to IPTV WITHOUT encryption Install an external Set Top Box: HDMI-IN input ready for external STB (ADD-ON A0000915) INTERNET IPTV (E.G.
Page 35
SKILLRUN (DJJ) Pre-Installation Requirements Rev. 2.0 COAX QAM Pro:IDIOM®: ATSC/ QAM-B Pro:IDIOM® UNITY3.0 VERSION “-A“ + UPGRADE KIT A0000845 Broadcast System CABLE TV: QAM-B (64/256 QAM –ITU J83 Annex B) – Channel spacing 6 MHz DIGITAL TV : ATSC (free to air) ANALOG TV: Not available RADIO FM: Not available RF INPUT: F-Type connector...
SKILLRUN (DJJ) Pre-Installation Requirements Rev. 2.0 6.6 UNITY 3.0 - VERSION (-I) STANDARD OPTIONS - JAPAN ▪ Analog TV + FM Radio ▪ Digital TV ISDB-T (JAPAN) with Smart Card reader ▪ IPTV (LAN- mpeg over UDP/RTP) not encrypted + Internet via LAN ▪...
Page 37
SKILLRUN (DJJ) Pre-Installation Requirements Rev. 2.0 IPTV Pro:IDIOM® UNITY 3.0 VERSION “-I” + UPGRADE KIT A0000897 (Tuner “I” need to be removed) Codecs MPEG-2 MP@HL. MPEG -4 pt10 AVC/H.264 HP@L4-VC1 Video Resolutions Decodes up to 720p and 1080p Audio MPEG 1, 2, MP3, DD/DD+, AAC, AC3 IPTV Input Ethernet 10/100 BaseT via RJ-45 shielded connector IPTV Protocols...
FOR SKILLRUN UNITY 5000 / 7000) The training format - SKILLRUN CLASS - can function only if the customer cover the pre-installa- tion requirements of SKILLRUN UNITY 5000 / 7000 and UNITY SELF. SKILLRUN CLASS - COMPATIBILITY SKILLRUN UNITY 5000...
SKILLRUN (DJJ) Pre-Installation Requirements Rev. 2.0 LIST OF CHANGES FOR MANUAL REVISION The main changes made to this manual, are listed below in chronological order. 9.1 REVISION 2.0 Inserted the pre-installation requirements and technical data about SKILLRUN TX 500 with the new TX (10”) interface.
Need help?
Do you have a question about the SKILLRUN UNITY 5000 and is the answer not in the manual?
Questions and answers
How do I log in to change my router password on a SkillRun Unity 5000 ?