Horizontal Terminations - Flex Vent 4" X 6-7/8 - Regency Fireplace Products City Series CC40LE-NG12 Owners & Installation Manual

Table of Contents

Advertisement

Horizontal Terminations -
These venting systems, in combination with the CC40LE/CC40RE Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Intertek.
The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in "Exterior Vent Termination Locations" section.
Regency
Direct Vent (Flex) System Termination Kits includes all the parts needed to install the CC40LE/CC40RE using a flexible vent.
®
FPI Kit # Length
Contains:
#946-
2 Feet
1.
6-7/8" flexible outer liner (Kit length)
513
2.
4" flexible inner liner (Kit length)
3.
spring spacers
4.
thimble
#946-
4 Feet
5.
AstroCap termination cap
515
6.
screws
7.
tube of Mill Pac
#946-
10 Feet
8.
plated screws
516
9.
S.S. screws #8 x 1-1/2" drill point
Notes:
1. Liner sections should be continuous without any joints
or seams.
2. Only Flex pipe purchased from Regency
for Flex installations
3. Horizontal vent must be supported every 3 feet.
4. Flex system can only be used up to a maximum
continuous vent length of up to 10 feet. If longer runs
are required, rigid pipe must be used.
Flex Vent 4" x 6-7/8"
may be used
®
installation
Vent Guard - if required*
(Part #946-506/P)
City Series CC40E-12 |
55