70
Example: Pressure accumulator MS40-8
1
Location of the pressure accumulators on an MS40–8
Depending on the machine type and its equipment, one or more pressure
accumulators (1) are installed on the machine (be sure to observe the hydraulic
diagrams valid for this machine type).
Caution for systems with pressure accumulators! Pressure accumulators such
as bubble reservoirs, diaphragm accumulators, piston accumulators may only be
serviced by specialists and tested by "qualified persons for pressure vessels". The
Industrial Safety Regulation BetrSichV is binding here.
The locally valid guide lines and regulations must be taken into
consideration.
Power off the machine, depressurize the hydraulic system by
opening the accumulator relief valve(s), and protect against
accidental power on.