3.
If more than 50 L of hydraulic fluid have to be refilled within 21
working shifts or one week, the hydraulic system must be
checked for leaks.
Check for leakage. Also check all screw connections and fluid lines, as well as
all hydraulic devices such as valves, sensors and filters of the system
4.
Pressurized fluids exiting from damaged or incorrectly
installed fluid lines.
General cuts or eye injuries.
Danger
Power off the machine and depressurize the hydraulic system
before any maintenance activities. Secure the machine against
being switched on. Wear personal protective equipment.
Check fluid lines for damage such as buckling and abrasions, and for liquid
leaks. If necessary, replace fluid lines. Record the age or date of replacement
of the fluid lines. Enter in the service, testing and maintenance schedules or
logs.
Alternatively, the following procedure can be used!
If immediate replacement of the fluid line(s) is not possible, determine the part
data and order the fluid line(s). If necessary, consult the machine manufacturer
or its representative as when schedule the replacement.
5. Conduct a finger test of screw connections, fittings, etc. to see whether they are
wet, and check for tightness.
Alternatively, the following procedure can be used!
Tighten loose and/or wet screw connections.
6. Check components for damage.
Alternatively, the following procedure can be used!
Log damage to components and initiate follow-up measures such as ordering,
and schedule the replacement with the machine manufacturer or its country
representative.