CITY SERIES
installation
11. Loosen 4 screws in locations shown below (2 at front and 2 at rear)—slide
burner to the left away from the orifice and lift out.
front
screw locations
12. Remove burner orifice with a 3/8" wrench. Use another wrench to hold
on to the elbow behind the orifice. Discard orifice. Reinstall new burner
orifice LPG stamped #53 and tighten.
CV40E shown
13. Remove pilot retainer clip with pliers and pull off the pilot cap to expose
the pilot orifice.
Pilot retainer clip
80
| City Series CB40E-12
920-040
back screw locations
Burner Orifice
Location
14. Unscrew the pilot orifice with the allen key; then replace with the LPG
pilot orifice and the pilot cap, provided in the kit.
15. Reinstall pilot cap and pilot retainer clip.
15. Reinstall pilot cap and pilot retainer clip.
16. Prior to installing burner—adjust aerations settings - to 1/4" for
16. Prior to installing burner—adjust aerations settings - to 3/8" for LP.
LP.(CB40E/CC40E/CV40E/CB40EPV/CV40EPV/CC40EPV) or 3/8"
(CB40E-1/CC40E-1/CV40E-1) Reinstall burner (see Step 13).
17. Reinstall burner (see step 13).
17. Ensure the pilot light is in the correct orientation to the Burner. Recon-
18. Ensure the pilot light is in the correct orientation to the Burner. Reconnect
nect the gas and electrical supply to the appliance. Start the appliance.
the gas and electrical supply to the appliance. Start the appliance. (see
(see section on Lighting Instructions) Ensure that pilot and burner igni-
tion is completed without delay. Check both your inlet and outlet pres-
section on Lighting Instructions) Ensure that pilot and burner ignition is
sures at full load. With a soapy solution, leak test the entire system.
completed without delay. Check both your inlet and outlet pressures at
Verify both the correct flame and pilot appearance.
full load. With a soapy solution, leak test the entire system. Verify both
the correct flame and pilot appearance.
18. See Gas Pipe Pressure Testing in manual.
19. See Gas Pipe Pressure Testing in manual.
Min. Supply Pressure
Manifold Pressure - High
Manifold Pressure - Low
Orifice Size
Maximum Input
Minimum Input
Altitude
Installer Notice:
These instructions must be left
with the appliance
2
City Series
LP SYSTEM DATA
11" WC (2.73kpa)
10.5" WC (2.62 kpa)
2.9" WC (0.72 kpa)
#53 DMS
28,500 Btu/h (8.35 kW)
15,500 Btu/h (4.54 KW)
0-4500 ft (0-1372m)
.
02.13.19