Regency City Series Owners & Installation Manual page 40

Hide thumbs Also See for City Series:
Table of Contents

Advertisement

CITY SERIES
installation
2. Install Part B1 + B2 to Part A with 2 screws on each side from the front
of the unit.
B2
B1
Part B1 to A - screws go in from front
3. Install Part J (x 2) to Parts B1 + B2 with 4 screws each (2 top - 2 bot-
tom) - screw locations shown below.
J
Part J install to Part B1 + B2
Part J screw locations
40
| City Series CB40E-12
919-669c
4. Slide unit into position. Check to ensure that the unit is level from front
to back and side to side and Parts A + B are square. Secure the unit
with framing to the wall studs with 2-1/2"-3" (64 mm - 76 mm) wood
screws. Use 8 screws and secure to 4 studs minimum. Install vent-
ing before proceeding further with framing kit construction. Refer
t t o o o o l l t t i i p p
to manual for venting instructions.
B1/B2 must be
secured to framing/
studs with a minimum
of 8 screws.
Secure Framing to Wall Studs with wood screws
5. Install one screw (lower screw position) into B1 and B2. Hang the
pre assembled RIGHT sidewall off the 2 screws using the keyhole
opening on the sidewall.
6. When sidewall is in position - install the second screw in both B1 and
B2 and tighten both screws to secure sidewall.
Install Pre Assembled Sidewall
7. Repeat Steps 5 & 6 on the left side to install opposite pre assembled sidewall.
Install Pre Assembled Sidewall (opposite)