NOT ENOUGH WATER
When the water tank (2) and the process
–
chamber (7) are empty, the unit will switch
off, you will hear 3 short sound signals, and
all the indicators on the control panel will
start flashing. After some time the indicators
will go out.
Remove the lid (1) from the water tank (2).
–
Fill the tank (2) with the necessary amount of
–
water not exceeding the maximal level mark
(3) «МАКС», then install the lid (1) back to
its place.
Switch the unit on for further operation.
–
CLEANING AND CARE
WARNING! Always switch the air humidifier off
and unplug it before maintenance works or clean-
ing.
Hard water causes appearance of mineral depos-
its (scale) in the process chamber (8) and in the
water tank (2) that leads to improper operation of
the unit. To avoid it:
сlean the tank every three days, this will help
–
to prevent scale buildup in the tank and the
process chamber. It also prevents the bacte-
ria growth.
use filtered and settled water. If tap water is
–
hard, it is recommended to mix tap water with
distilled water in proportion 1:1. If tap water is
too hard, mix it with distilled water in proportion
1:2 or use distilled water only.
Change water in the water tank (2) twice a
–
week.
Thoroughly wash the process chamber (7) and
–
the water tank (2) with neutral detergent solu-
tion twice a week.
TROUBLESHOOTING
Problem
Possible causes
No "mist"
The unit is connected
improperly
The unit is off
Water tank is empty
or there isn't enough
water in the tank
Foreign smell
First use
appears during
the operation
Dirty or stale water
To clean the «sprayer» (9) from the mineral
–
deposit (scale) add 5-10 drops of detergent
on it and wait for approximately 10-15 minutes.
Remove the scale from the «sprayer» surface
with a soft brush, and then wash the process
chamber (7) with neutral detergent solution.
Rinse the process chamber several times. Wipe
–
the process chamber with a soft cloth.
Clean the air humidifier body (6) with a soft,
–
slightly damp cloth, and then wipe it dry.
Clean the air inlet (4) and the air inlet grid on the
–
unit body (6) bottom as it becomes dirty.
To clean the float (8), remove it. Lift the float
–
and remove it from the holder. Clean the float
(8) from mineral scale.
Install the float (8) back to its place, making
–
sure there is no seizure in the axial movement
(rotation) of the float (8).
Notes:
do not immerse the air humidifier body into
–
water or other liquids;
do not use abrasives or solvents for cleaning
–
the sprayer (9);
you can use a descaling agent for kettles as a
–
detergent for the sprayer (9) and the float (8),
strictly following the instruction for this sub-
stance.
STORAGE
Pour the water out of the tank and make sure
–
that the process chamber and the sprayer are
dry before taking the unit away for storage.
Do not keep water inside the tank (2) or the pro-
–
cess chamber (7) of the unit.
Keep the air humidifier in a dry cool place away
–
from children and disabled persons.
Troubleshooting
Check if the power plug is inserted into the mains socket.
Switch the unit on by pressing the button (15).
Fill the water tank (2) with enough water.
Disconnect the unit from the mains. Remove the water tank,
remove the lid and pour the water out of the water tank, then
leave the water tank in a dry cool place for 12 hours.
Unplug the unit, remove the water tank, remove the lid, pour
the water out of the water tank and clean the tank
(as described in the chapter "Cleaning and care"), then fill it
with clean water.
5
ENGLISH