Cleaning And Care; Troubles And Troubleshooting - Vitek VT-2352 Manual Instruction

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Unplug the air humidifier. Turn the mist nozzle
(1) counter-clockwise, remove the cover (3)
form the water tank (4) by pulling the nozzle
(1). Fill the water tank (4) with water, reinstall
the cover (3) back to its place, and switch on
the air humidifier.
At the end of the work, turn off the humidifier,
unplug the unit.

CLEANING AND CARE

WARNING! Always switch the air humidifier
off and unplug it before maintenance works or
cleaning.
Water Mineral Filter
The unit is equipped with a permanent mist
outlet (6) with a water mineral filter (6), which
does not need to be replaced. Every 3-5 days
remove the filter (open the water tank and
carefully pull the air outlet (2) to remove the
«mist» outlet with the water mineral filter (6),
as shown in the figure above). Wash the mist
outlet with the water mineral filter (6), and
install it back into place.
Note: - the filter (6) cannot completely clean the
water from mineral deposit and is an additional
means of water cleaning.
Hard water causes mineral residue to appear
on the ultrasonic converter (7) and inside the
water tank (4) which hinders the operation of
the air humidifier and causes white deposits
to form on furniture objects.

TROUBLES AND TROUBLESHOOTING

Problem
No button or numeric
indications (13, 14, 15, 16,
17, 18, 19, 20) appear, or the
«mist» is not being released.
Mist smells unpleasantly.
Low mist release intensity
Foreign noise during the air
humidifier operation
To prevent this, perform weekly cleanings of
the ultrasonic converter (7) and change water
in the water tank (4) as often as possible.
Before extended periods of non-usage:
empty the water tank (4), wash the water tank
(4), wash and clean the ultrasonic converter
(7), the water filter (6), thoroughly dry the unit
and take it away for storage.
Weekly care
Once a week perform a thorough washing of
the water tank (4) using a neutral detergent.
Then rinse with water carefully.
Wipe the motor unit (11) of the humidifier with
a slightly damp soft cloth and then wipe it dry.
Do not immerse the motor unit (11), power
cord or plug of the humidifier into water or any
other liquids. Provide that no liquid gets inside
the motor unit (11) of the humidifier.
Do not use solvents or abrasives to clean the
surface of the motor unit (11) and the water
tank (4).
STORAGE
Before extended periods of non-usage and
taking the air humidifier away for storage,
make sure that all its parts, including the fil-
ter (6), are dry.
Only take the air humidifier away for storage
with an empty water tank.
Keep the air humidifier away from children in a
dry, dark and cool place.
Possible causes
Troubleshooting
No supply voltage.
Connect the unit to the mains.
Plug another, known good appliance to the
socket to make sure that the socket works
properly.
Water tank is empty.
Fill the water tank with water.
First use of the unit.
Pour out the water and leave the tank open
for 12 hours in a cool darkened place
Dirty or stale water.
Unplug the unit, remove the water tank,
pour out the water, wash the tank and fill it
with clean boiled or distilled water.
Clogged nozzle (1)
Unplug the air humidifier, perform the
or ultrasonic
cleaning of the nozzle (1) or the ultrasonic
converter (7).
converter (7).
The unit is placed
Unplug the unit and level the unit body or
on an uneven or
move the air humidifier to another place.
unstable surface.