6.20 Selecting Centronics Type

SYSVAR(25) = <value>
<value> = 0
<value> = 1
<value>= 2

6.21 Clearing Media Feed Data at Headlift

SYSVAR(28) = <value>
<value> = 0
<value> = 1

6.22 Minimum Gap Length

SYSVAR(37) = <value>
<value>

6.23 Equal Safe for TESTFEED

SYSVAR(38) = <value>
<value>
Intermec Direct Protocol v7.80 Programmer's Reference Manual
Standard type:
500 ns ACK, BUSY inactivated after ACK fi nishes (default).
IBM/Epson type:
2500 ns ACK, BUSY inactivated as soon as ACK pulse starts.
Classic type:
BUSY deactivated, wait 2500 ns, then give 2500 ns pulse on ACK.
Media feed data not cleared at headlift (default).
Media feed data cleared at headlift.
specifi es the minimum size of the gap, slot, or black marks that should be
detected by the label stop/black mark sensor (1-32 dots) in connection
with PRINTFEED and FORMFEED. Default is 1 mm/0.039 inches (8 or 12 dots
depending on printhead density).
specifi es how many consecutive detections of a gap or black mark the label
stop/black mark sensor will have to make before the fi rmware registers it
as a gap or mark (0-255). Default is 6.