is used for multi-line text fi elds.
PRBOX
PRBOX | PX <box height>,<box width>,<line thickness>,"<input data>"[,<hor.
off set>[,<vert. off set>[,"<line delimiter>"[,"<control string>"]]]]]
<box height>
<box width>
<line thickness>
<input data>
<hor. off set>
<vert. off set>
<line delimiter>
<control string>
The height, width, and line thickness parameters are the same as when
creating an ordinary box fi eld, see Chapter 4.6. However, you can set the
line thickness to 0, which gives an invisible box.
The input data allow max. 20 lines with max. 300 characters on each
line. Double-byte fonts cannot be used. In all other respects, this param-
eter corresponds to the input data in
The horizontal and vertical offset is used to specify the position of the
text frame in relation to the inner edge of the border line. The vertical
offset also controls the line spacing, which means the distance between
the bottom of the character cells on one line and the top of the character
cells on the next line. Note that the alignment affects both how the box
is located in relation to the insertion point and how the text frame is
located in relation to the box, see Chapter 4.2.
By default, the input data wraps to a new line each time a carriage return
or linefeed character is entered. You can optionally replace those charac-
ters with another character or a series of characters.
By default, text lines are hyphenated from the last space or position
marked by a hyphen sign (-). The hyphen sign will only be printed as the
last character on a line. There are many advanced features for control-
ling the hyphenation and handling of long-spelling words. Refer to the
Intermec Fingerprint v7.80, Programmer's Reference Manual for syntax and
explanations of the hyphenation control string.
Intermec Direct Protocol v7.80 Programmer's Reference Manual
is the height of the box in dots (1-6000).
is the width of the box in dots.
is the line thickness in dots (0-6000).
is max. 20 lines of text, each with max. 300 single-byte characters.
is the horizontal distance between the box line and the text frame (-100 to
+100 dots). Default: 0.
is the vertical distance between the box and the text frame and between
each text line (-100 to +100 dots). Default: 0.
is a string used to replace the default carriage return or line feed character.
is a string for hypenation control, see Intermec Fingerprint v7.80, Programmer' s
Reference Manual.