RS-232 or RS-422/485 COM2 Interface Update
Description:
Defines the interface for the COM2 communications port. If you have a 2460 with an
enhanced input/output board, you can use COM2 for either RS-232 or RS-422/485
communications.
The RS-485 interface is only available on terminals using Multi-Drop protocol in a
CrossBar network.
Syntax:
YK2
Acceptable values for data are:
0
1
Default:
RS-232
Bar Codes:
To set the interface for COM2, scan one of these bar codes:
Enable RS-232 Interface
*$+YK2.0*
*$+YK2.0*
Symbology Identifiers
Description:
With firmware version 6.20 and later, you can use symbology identifiers to indicate the
type of data being sent by prepending an identifier to the data. You can prepend one of
the following types of character strings to identify which symbology the data is using:
AIM ISO/IEC Standard The AIM Standard symbology identifiers consists of a three-
character structure indicating the symbology and the optional features of the
symbology. For more information about the AIM Standard for symbology identifiers,
refer to the AIM ISO/IEC Standard.
User-Defined ASCII Character String The user-defined symbology identifier is one to
four ASCII characters in length. You can configure user-defined symbology identifiers
to assign custom identifier strings to the bar code symbologies.
The Symbology Identifiers command contains four parameters. To disable or enable all
symbology identifiers to the ISO/IEC Standard, you need to configure the first two
parameters. To enable a user-defined symbology identifier, you need to configure all
four parameters.
C39
nugget
.
data
RS-232
RS-422/485
Configuration Command Updates
Enable RS-422/485 Interface
*$+YK2.1*
.
$+YK2
1*
15