Trakker Antares 2455/2475 DC Power Supply Installation Instructions

Troubleshooting Table

The following information assumes that your 2455 or 2475 does not work and that the
problem is caused by the power supply or the power supply cables.
You Observe
Power supply LED is lit.
Power supply LED is not lit.
Input voltage is normal for
this kit at the power supply
input connector, and the
power supply LED is not lit.
Input voltage is not normal
for this kit at the power
supply input connector but is
present at the vehicle power
source.
The power supply has automatic over-voltage, over-current, over-temperature, and
shorted-output protection. If a fault other than over-current activates the protection, the
power supply output condition indicator light will go out and you must then reset the
power supply. Over-current conditions are self-correcting; therefore, intermittent, short-
duration short-circuit conditions or low resistance in the power supply output will cause
the power supply LED to blink off and on.
To reset the power supply
1. Disconnect the power supply input cable from the DC power supply for 10 seconds.
2. Reconnect the power supply input cable.
Meaning
Power supply is working.
No output power from
power supply.
Power supply is not
working.
No input power to the
power supply.
Solution
Test or substitute the
2455/2475 power cable.
Reset the power supply. For
help, see the 2455 or 2475
user's manual.
Test for input voltage.
Replace the power supply.
Replace the fuse in the fused
power cable if voltage is NOT
present at connector.
Replace the power supply
input cable if input voltage is
still not present at the
connector.
If you have a remote switch
installed, make sure the DC
power supply is turned on.