Download Print this page

ADTRAN NetVanta 950 IAD Quick Configuration Manual page 19

Hide thumbs Also See for NetVanta 950 IAD:

Advertisement

Create a T1 to Serial Cross-Connect
For this example we will map DS0s from a T1 WAN interface to a serial port. The
NetVanta 950 IAD T1/V.35 Expansion Module (1200798L1) must be installed for this
application to work. The following steps assume the Global Configuration mode is currently
active. Verify that the prompt of your unit displays (config)#.
1. Enter interface serial 1/1 to access the configuration parameters for the serial interface.
2. Enter config terminal to enter the Global Configuration mode.
3. Enter interface t1 0/1 to access the configuration parameters for the WAN 0/1 interface.
4. Enter tdm-group 1 timeslots 1-12 speed 64 to create a TDM group for DS0 1 through 12 on
the T1 network (t1 0/1) at the speed of 64 kbps for each DS0.
5. Enter exit to return to Global Configuration mode.
6. Enter cross-connect 1 t1 0/1 1 ser 1/1 to connect DS0 1 through 12 of the T1 network to the
serial 1/1 (V.35) interface.
Create a T1 to T1 Cross-Connect
For this example we will map DS0s from a T1 WAN interface to another T1 WAN interface.
The NetVanta 950 IAD T1/V.35 Expansion Module (1200798L1) must be installed for this
application to work.
1. Enter interface t1 0/1 to access the configuration parameters for the WAN 0/1 interface.
2. Enter tdm-group 1 timeslots 1-12 speed 64 to create a TDM group for DS0s 1 through 12
on the T1 network (t1 0/1) at the speed of 64 kbps for each DS0.
3. Enter exit to return to Global Configuration mode.
4. Enter interface t1 1/1 to access the configuration parameters for the T1 interface (t1 1/1).
5. Enter tdm group 2 timeslots 1-12 speed 64 to create a TDM group for DS0s 1 through 12
on the Expansion Slot T1 interface at a speed of 64 kbps for each DS0.
6. Enter cross-connect 1 t1 0/1 1 t1 1/1 2 rbs to connect DS0s 1 through 12 of the T1 network
to the Expansion Slot T1 interface (rbs is optional and is used when doing robbed-bit
signaling with voice applications).
Save the Configuration
1. Verify that the prompt of your unit displays IAD#.
2. Enter copy running-config startup-config to save the current configuration to memory.
3. Enter exit to close the configuration session.
61200788L1-42A