2. Slide the keyed insets on the bottom of the unit's chassis securely onto the screws.
f
CAUTION!
The NetVanta 1560-08 must be mounted in the face-down orientation when wall mounted.
Supplying Power to the Switch
To connect the AC power cord to the switch, complete the following steps.
1. Connect the AC power cord to the AC power receptacle on the rear panel of the switch.
2. Connect the other end of the AC power cord to a properly grounded AC power outlet. The AC branch circuit socket-outlet must be installed near the
equipment and must be easily accessible.
3. Confirm that the power is connected properly. The SYSTEM LED should be ON (see
g
NOTE
The installation of this product must comply with the national, state and local electrical code requirements, as applicable. The AC branch circuit
overcurrent protection must be a fuse or circuit breaker rated 125 VAC, 20 Amps maximum or 250 VAC, 16 Amps maximum. A readily accessible
disconnect device that is suitably approved and rated must be incorporated in the field wiring.
f
CAUTION!
It is recommended that an external AC Surge Protection Device be installed at the AC input connection to the local AC-Powered product. The Surge
Protection device should provide L-N, L-G, and N-G protection. It is also recommended that the device contains a visual 'GOOD' indicator.
f
WARNING!
This equipment incorporates double pole/neutral fusing. If the neutral fuse opens and the line fuse does not open, voltage could still be present in the
unit.
4
Figure 7. Attaching the Switch to the Wall
Figure 8. Connecting the AC Power Cord
"SYSTEM Status
LED").
617101561F1-13A