P/N 0463880_E

CLEANING HONEYCOMB ASSEMBLIES

Honeycombs should be cleaned every six months.
Dirty honeycombs will cause merchandisers to
perform poorly. The honeycombs may be cleaned
with a vacuum cleaner. Soap and water may be
used if all water is removed from the honeycomb
cells before replacing. Be careful not to damage
the honeycombs.
Multi-deck Cases
1. Loosen or remove screw to free honeycomb.
2. Clean and dry the honeycomb.
3. After cleaning, replace honeycomb and slide
retainer forward. Reinstall screw.
Damaged honeycomb must be replaced.
LED Light Bars
Honeycomb
Air Straightener
Fluorescent Lamps
Honeycomb
Air Straightener
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
Retainer
Screw
Retainer
Screw
Single Deck Cases
1. Using a flat object such as a screw driver,
compress the honeycomb and remove it
from its retainer.
2. Clean and dry the honeycomb.
3. After cleaning, replace in reverse order.