Installation; Nsf Certification; Location; Shipping Damage - Hussmann Impact Excel M5X Installation And Service Manual

Medium temperature meat, delicatessen, dairy and produce merchandisers
Hide thumbs Also See for Impact Excel M5X:
Table of Contents

Advertisement

P/N 0463880_E

NSF CERTIFICATION

These merchandisers are manufactured to meet
ANSI / National Sanitation Foundation (NSF
Standard #7 requirements. Proper installation is
required to maintain certification. Near the serial
plate, each case carries a label identifying the
type of application for which the case was
certified.
ANSI/NSF-7 Type I – Display Refrigerator / Freezer
Intended for 75°F / 55%RH Ambient Application
ANSI/NSF-7 Type II – Display Refrigerator / Freezer
Intended for 80°F / 55%RH Ambient Application
ANSI/NSF-7 – Display Refrigerator
Intended for Bulk Produce

LOCATION

These merchandisers are designed for displaying
products in air conditioned stores where tempera-
ture is maintained at or below the ANSI / NSF-7
specified level and relative humidity is maintained
at or below 55%.
Placing refrigerated merchandisers in direct
sunlight, near hot tables or near other heat sources
could impair their efficiency.
Like other merchandisers, these are sensitive to air
disturbances. Air currents passing around
merchandisers will seriously impair their
operation. Do NOT allow air conditioning,
electric fans, open doors or windows, etc. to
create air currents around the merchandisers.
Product should always be maintained at proper
temperature. This means that from the time the
product is received, through storage, preparation
and display, the temperature of the product must
be controlled to maximize the life of the product.
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.

INSTALLATION

Excel merchandisers have internal frames.
®
)
A 3 inch (76 mm) space between the rear
of the merchandiser and wall must be
maintained for air circulation. However, in
high ambient conditions, sweating may
still occur. If this happens install a method
of forced ventilation such as a fan
ventilation kit.

SHIPPING DAMAGE

All equipment should be thoroughly examined for
shipping damage before and during unloading.
This equipment has been carefully inspected at
our factory. Any claim for loss or damage must be
made to the carrier. The carrier will provide any
necessary inspection reports and/or claim forms.
Apparent Loss Or Damage
If there is an obvious loss or damage, it must be
noted on the freight bill or express receipt and
signed by the carrier's agent; otherwise, carrier
may refuse claim.
Concealed Loss Or Damage
When loss or damage is not apparent until after
equipment is uncrated, retain all packing materials
and submit a written request to the carrier for
inspection, within 15 days.
Do not walk or put heavy objects on case.
CAUTION
!
Medium Temperature
1-1
Excel

Advertisement

Table of Contents
loading

This manual is also suitable for: