CLEANING HONEYCOMB
ASSEMBLIES
Honeycombs should be cleaned every six
months. Dirty honeycombs will cause
merchandisers to perform poorly. The
honeycombs may be cleaned with a vacuum
cleaner. Soap and water may be used if
all water is removed from the honeycomb
cells before reassembling. Be careful not to
damage the honeycombs.
1. Pull the honeycomb assembly out of the
interior top panel to remove it.
2. Clean and dry the honeycomb.
A
3. After cleaning, reassemble in reverse
order of removal.
DISCHARGE AIR SENSOR ONLY
DEFLECTOR
DEFLECTOR
DISCHARGE
DISCHARGE
LOOKING AT TOP
LOOKING AT TOP
FRONT LEFT SIDE
FRONT LEFT SIDE
OF CASE
OF CASE
CLEANING STAINLESS STEEL
SURFACES
Use non-abrasive cleaning materials, and
always polish with grain of the steel. Use
warm water or add a mild detergent to the
water and apply with a cloth. Always wipe
rails dry after wetting.
Use alkaline chlorinated or non-chlorine
containing cleaners such as window cleaners
and mild detergents. Do not use cleaners
containing salts as this may cause pitting
and rusting of the stainless steel finish. Do
not use bleach.
P/N 3143042_B
M
aIntenanCe
VIEW OF TOP OF CASE
U.S. & Canada 1-800-922-1919 • Mexico 800-890-2900 • WWW.HUSSMANN.COM
Clean frequently to avoid build-up of
hard, stubborn stains. A stainless steel
cleaning solution may be used periodically
to minimize scratching and remove stains.
Rinse and wipe dry immediately after
cleaning. Never use hydrochloric acid
(muriatic acid) on stainless steel.

CLEANING COILS

Never use sharp objects around coils. Use a
soft brush or vacuum brush to clean debris
from coils.
Do not puncture coils!
DISCHARGE AIR SENSOR ONLY
Do not bend fins. Contact an authorized
service technician if a coil is punctured,
cracked, or otherwise damaged.
Do NOT use chlorine or ammonia-based
HACCP
SENSOR
cleaners to clean aluminum coils.
1.50
APPROX
ICE in or on the coil indicates the
DETAIL A
refrigeration and defrost cycle is not
TOP LEFT SIDE
OF CASE
operating properly. Contact an authorized
SCALE 1:1.33
service technician to determine the cause of
icing, and to make adjustments as necessary.
To maintain product integrity, move all
product to a cooler until the unit has
returned to normal operating temperatures.
Product will be degraded and may
spoil if allowed to sit in a non-
refrigerated area. Do NOT allow
cleaning agent or cloth to contact food
FRONT OF CASE
THERMOMETER
SENSOR
DISCHARGE
AIR SENSOR
1.50
APPROX
product.