P/N 0463880_E

MERCHANDISER ELECTRICAL DATA

Technical data sheets are included with this
manual. The data sheets provide case electrical
data, electrical schematics, parts lists and perfor-
mance data. Refer to the technical data sheets and
case serial plate for electrical information.

ELECTRICAL CONNECTIONS

All wiring must be in compliance with NEC and
local codes. All electrical connections are to be
made in the electrical raceway or Handy Box.
CAUTION
!
Optional T8 rail lights and
optional Quick Connect spray hose
or field-installed misting system
shall not be used together.
Leads for all electrical circuits are identified by a colored plastic band: neutral
wire for each circuit has either White insulation or a White plastic sleeve in
addition to the color band.
P
............R
INK
EFRIG
L
B
..R
IGHT
LUE
EFRIG
D
B
..D
ARK
LUE
EFROST
P
........C
URPLE
ONDENSATE
B
........F
ROWN
AN
G
* .......G
REEN
ROUND
ELECTRICIAN NOTE: Use copper conductor wire only.
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
WIRING COLOR CODE
. T
L
HERMOSTAT
OW
. T
N
HERMOSTAT
ORM
T
. T
ERM
HERMOSTAT
H
EATERS
M
OTORS
*E
ITHER COLORED
CASE MUST BE GROUNDED

FIELD WIRING

Field wiring must be sized for component
amperes stamped on the serial plate. Actual
ampere draw may be less than specified. Field
wiring from the refrigeration control panel to the
merchandisers is required for defrost termination
thermostats and for optional refrigeration
thermostats. When multiple merchandisers are on
the same defrost circuit, the defrost termination
thermostats are wired in series.
A A L L W W A A Y Y S S C C H H E E C C K K T T H H E E S S E E R R I I A A L L P P L L A A T T E E F F O O R R
C C O O M M P P O O N N E E N N T T A A M M P P E E R R E E S S

IDENTIFICATION OF WIRING

Leads for all electrical circuits are identified by
colored plastic bands. These bands correspond to
the color code sticker (shown below) located
inside the merchandiser's raceway cover.
T
.
O
EMP
RANGE OR
T
.
T
..........L
EMP
AN
M
AROON
Y
ELLOW
R
ED
S
O
LEEVE
R
IGHTS
...R
ECEPTACLES
....D
H
EFROST
EATERS
........D
H
EFROST
EATERS
C
I
OLORED
NSULATION
Medium Temperature
2-5
. .
120V
208V
Excel

Advertisement

Table of Contents
loading

This manual is also suitable for:

Impact excel m5ep

Table of Contents