Undo the screw (F) to remove the lid (G).
4)
Connect the circuit-breaker (A) to the termi-
5)
nal board (H) of the appliance as shown in
the diagram and in the electrical system dia-
gram at the back of the manual. Use a cable c
with the following characteristics:
– Weight: ≥ than H05RN-F type (designation 245
IEC 57).
– Temperature of use: ≥ 70°C.
Important
When connecting, take care to connect the
neutral and earth lines.
Replace all when the operation is complete.
6)
Caution - Warning
Before doing any work, cut off the mains
electricity supply.
The manufacturer has tested the appliance with
its own mains gas, identifi ed by the sticker ap-
plied to the nameplate.
If the type of gas to be connected is diff erent
from that used for testing, proceed as follows.
Turn off the gas supply tap (A).
1)
Change the top burner nozzles (see pa-
2)
ges13-14).
Change the oven burner nozzle (see page 14).
3)
Change the top burner pilot light nozzles
4)
(see page 15).
Change the oven burner pilot light nozzle (see
5)
page 15).
If necessary, change the oven burner bushing
6)
(see page 15).
Adjust the minimum setting on the gas control
7)
valves of the hob burners (see page 11) and
the oven burner (see page11).
Remove the sticker from the nameplate and
8)
apply the new one to identify the gas being
used.
3319970_inst_GB_rev.1

CONVERSION OF GAS SUPPLY

On completion of the operation, make sure
that there are no gas leaks or malfunctions.
- 11 -