14.2
When replacing motor, place tip of screw and bearing into hole on frame first. Then pry up on
top frame while pressing motor in. Be sure corner of motor is captured on tab on back side of
frame. Plug motor into board.
Pry
Bearing
Section 15 - Picker Interface Board & Flex Cable
15.1
Remove lead screw assembly (see
Lead
Screw). Remove 3 screws securing interface board.
Remove board, pulling flex cable out through slots on picker frame.