mounting bases. Available steel mounting bases:
Washer
T-300
T-300
T-350
T-400
T-400
T-450
T-600
T-650
T-750
T-900/950
T-900/950
T-1200
T-1450
T-1800
If an elevated concrete pedestal is desired, it should be embedded and
tied into the existing floor. DO NOT install a pad on top of the existing
floor. Cut through existing floor as shown below. See Machine Mounting
Detail Figures for floor thickness and bolt sizes.
EXPANSION ANCHORS ARE NOT RECOMMENDED FOR USE IN CONCRETE
PEDESTALS BECAUSE THE ANCHORS ARE TOO CLOSE TO AN EDGE,
CAUSING IT TO BREAK OUT.
2.3
FOUNDATION AND PAD OPTIONS
All installations require reinforced concrete floors. Refer to appropriate
model Machine Mounting Detail Figures 1-1, 1-2 and 1-3 for minimum
floor thickness and minimum pad sizes. See mounting diagram for overall
washer dimensions.
Refer to appropriate model Figure 1-4 for side by side mounting
dimensions.
8514-296-001 REV K page 8
Part Number
Height
9945-094-003
8" (203 mm) Single Base
9945-094-004
8" (203 mm) Double Base
9945-121-001
8" (203 mm) Single Base
9945-089-001
6" (152 mm) Single Base
9945-089-002
6" (152 mm) Double Base
9945-123-001
6" (152 mm) Single Base
9945-098-001
6" (152 mm) Single Base
9945-145-001
6" (152 mm) Single Base
9945-117-001
6" (152 mm) Single Base
9945-103-001
4" (103 mm) Single Base
9945-118-001
6" (152 mm) Single Base
9945-124-001
6" (152 mm) Single Base
9945-145-001
4" (103 mm) Single Base
9945-159-001
4" (103 mm) Single Base