Dexter Laundry T-1800 Operators Manual Installation & Operation Instructions page 81

Commercial washers vended c-series control
Table of Contents

Advertisement

INVALID DRIVE
COMM ERROR6
8514-296-001 REV K page 81
Fault
Delay
Action
Solution
Drive is not the
correct Dexter
version of the
Condition
Delta MS300
drive
Delay
Action
Solution
VFD
Condition
Communication
Fault
Delay
Action
Solution
Delay time is 12 seconds.
Stop the machine and clear the cycle.
Keep the door locked until the machine has
stopped moving and then unlock the door.
Check VFD fault light before turning off
power. Turn the power off to the washer.
Wait one minute. Turn the power on to the
washer. If problem reappears, contact your
Dexter representative.
The error indicates the VF drive is not a
Dexter version of the Delta MS300 drive.
Immediate (after the Dexter indication
value is read from drive). Drive indication
value is read only at power up, before
starting a cycle, once every 24 hours, and
in factory test mode.
Stop the machine and clear the cycle. Keep
the door locked until the machine has
stopped moving and then unlock the door.
VFD has been replaced, disconnected, or
removed. Drive is not the correct Dexter
version of the Delta MS300 drive. Replace
drive with Dexter Delta MS300 drive.
This error indicates that a VFD exception
error is set and there is no VFD fault in the
VFD fault register and there is no COMM
ERROR 5 condition.
Occurs following the "DELAY" error (see
corresponding detail)
Stop the machine and clear the cycle.
Keep the door locked until the machine has
stopped moving and then unlock the door.
The washer will not restart until the power
is removed and re-applied.

Advertisement

Table of Contents
loading

Table of Contents