Foundation And Pad Options - Dexter Laundry T-675 EXPRESS PLUS Operator's Manual

Industrial washers
Hide thumbs Also See for T-675 EXPRESS PLUS:
Table of Contents

Advertisement

T-950/975
T-1450/1475 9945-145-001
If an elevated concrete pedestal is desired, it should be embedded and
tied into the existing floor. DO NOT install a pad on top of the existing
floor. Cut through existing floor as shown below. See Machine Mounting
Detail Figures for floor thickness and bolt sizes.
EXPANSION ANCHORS ARE NOT RECOMMENDED FOR USE IN CONCRETE
PEDESTALS BECAUSE THE ANCHORS ARE TOO CLOSE TO AN EDGE,
CAUSING IT TO BREAK OUT.
2.3

FOUNDATION AND PAD OPTIONS

All installations require reinforced concrete floors. Refer to appropriate
model Machine Mounting Detail Figures 1-1, 1-2 and 1-3 for minimum
floor thickness and minimum pad sizes. See mounting diagram for overall
washer dimensions.
Refer to appropriate model Figure 1-4 for side by side mounting
dimensions.
2.3.1 WASHER INSTALLATION ON EXISTING FLOOR:
2.3.2 WASHER INSTALLATION ON NEW FLOOR:
8514-290-001 REV E page 7
9945-118-001
6" (152 mm)
4" (103 mm)